IVDT SkidWeigh Classic SC5 Series Installation & Calibration Manual Download Page 4

Electrical Connections

All SkidWeigh systems operate from 12 to 55 VDC.

 

 

                                                                                                                                                   

Orange Wire (+) Key switch On position                                                                                                              
Brown Wire (-) Battery negative                                                                                                                                  
Red Wire, connect to RED wire of the pressure transducer cable                                                                                                
Black Wire, connect to BLACK wire of the pressure transducer cable                                                                                                                                               

                      

White Wire, connect to WHITE wire of the pressure transducer cable                                                     
Two Black Wires (two separate wires) are used for lift motor pump solenoid interface (SC5 system) 

Electric Pallet Truck Lift Motor Pump Solenoid Interface

Disconnect one wire from solenoid coil terminals, positive or negative side.               

Splice two wires from the indicator in series with disconnected wire and coil terminal.   

The SC5-OEM

 electric pallet truck weighing systems are the OEM’s version. Two wires from 

main wiring harness (

Yellow and Green wires

)are used for lift pump motor solenoid interface.                                                                                                

(System is supplied with two extension wires, Yellow and Green) 

 

Integrated Visual Data Technology Inc.  3439 Whilabout Terrace, Oakville, Ontario, Canada  L6L 0A7  

 

Orange Wire 

(+) Key switch On position                                                                                                              

Brown Wire 

(-) Battery negative    

Red Wire

 to pressure transducer cable                                                                                                

Black Wire

 to pressure transducer cable                                                                                                                                               

                      

White Wire

 to pressure transducer cable  

Disconnect one wire from solenoid coil terminals, positive or negative side. Splice two wires from 

the indicator in series with disconnected wire and coil terminal. 

SC5-OEM wiring harness

Green Wire                                      Yellow Wire

Summary of Contents for SkidWeigh Classic SC5 Series

Page 1: ...ation Calibration Manual Electric Pallet Truck Check Weighing Systems SkidWeigh Classic SC5 and SC5 OEM Series SC5EP Integrated Visual Data Technology Inc 3439 Whilabout Terrace Oakville Ontario Canada L6L 0A7 ...

Page 2: ...nd user with electro and hydraulic experience Here are two acceptable methods of making a wire connections Soldering your connections recommended Crimp connectors with the use of the proper crimping tool Regardless of the method you choose ensure that the connection is mechanically sound and properly insulated Use high quality electrical tape and shrink tubing where necessary This product is conne...

Page 3: ...ydraulic line for the installation of the pressure transducer Pressure Transducer Installation Precautions Before installation of the pressure transducer the hydraulic lift circuit must be pressure free Make sure that the installed pressure transducer will not touch any moving parts or vehicle assembly once installed while in normal operation The pressure transducer has a 1 4 18 NPT male thread Us...

Page 4: ...indicator in series with disconnected wire and coil terminal The SC5 OEM electric pallet truck weighing systems are the OEM s version Two wires from main wiring harness Yellow and Green wires are used for lift pump motor solenoid interface System is supplied with two extension wires Yellow and Green Integrated Visual Data Technology Inc 3439 Whilabout Terrace Oakville Ontario Canada L6L 0A7 Orange...

Page 5: ...Integrated Visual Data Technology Inc 3439 Whilabout Terrace Oakville Ontario Canada L6L 0A7 ...

Page 6: ...ks height for 3 4 seconds Load weight will be calculated and shown on LED indicator display Once the load weight is shown on LED Display the lift pump motor solenoid circuit will be in normal operational mode Electrical Power Short Circuit Protection All SkidWeigh systems are internally short circuit protected with a resettable fuse There is no need to install external inline fuse in the orange wi...

Page 7: ...e version for the moment and in Mode 8 will be shown System weighing function is ready to be calibrated Empty Forks Calibration With lowered empty forks on the ground the Mode 8 will shown Use paper clip and press and hold M button for approx 5 seconds Mode 8 will change to Mode 0 Activate and hold lift control switch until lift pump motor stops automatically The LED Display will go blank and with...

Page 8: ...ue of 4000 four digits only Make sure that 5th digit is 0 value Next step is to press M button to advance to Mode 6 With loaded forks on the ground and LED Display showing Mode 6 activate and hold lift control switch until loaded forks are automatically stopped at pre determined forks height During the measurement cycle LED Display will go blank for moment System is calculating the load weight val...

Page 9: ... pre determined forks height During the measurement cycle LED Display will go blank for moment System is calculating the load weight value Within few seconds LED Display will show the load weight Our example 583 Depending on system set up application the value could be in pounds or kg Integrated Visual Data Technology Inc 3439 Whilabout Terrace Oakville Ontario Canada L6L 0A7 System Power Switch N...

Reviews: