Note:
Valid operator ID# card is required during system installation to enable vehicle operation
(Verification of electrical connection of the BLUE and GREEN wires connected in series to one
of the vehicle seat switch wire) and to be able to access the “Administration Menu”.
Selecting the mounting location for digital indicator
Use the mounting bracket with the anti vibration mount and fasten digital indicator on the vehicle dashboard, side railing
on the right hand side or preferably on the overhead guard. There are many examples of mounting locations that will
depend on the vehicle model. However, additional mounting items such as a flat brackets may be needed to help secure
the unit to upper right corner of the guard or side railing.
Choose the correct location and make sure that:
- Indicator is visible and within reach of the operator
- Location so that operator has a clear unobstructed view of the working environment
Electrical connections
All SkidWeigh RFID equipped systems operate from 12 to 55 VDC.
Orange Wire
(+) Ignition switch
Brown Wire
(-) Battery negative
Internal relay connections to be used to enable vehicle usage
(Dry contacts)
BLUE Wire,
common
GREEN Wire
, N. O. contact
Integrated Visual Data Technology Inc. 3439 Whilabout Terrace, Oakville, Ontario, Canada L6L 0A7
Power Supply 12 to 55 VDC
Ignition ORANGE WIRE
Battery Negative (-) BROWN WIRE
Use two wires
BLUE
and
GREEN
and connect
them is series with vehicle seat switch wire
Normally Open Contacts
(+)
ORANGE Wire
,
Connect to ignition switch
(-)
BROWN Wire,
Connect to battery negative