AUTO-OFF FEATURE
When the trigger is released, the dynamic pressure automatically shuts
off the washer’s motor. When the trigger is then pressed again, the
pressure drop automatically activates the motor, and the new pressure
begins building up. To ensure that this automatic shutoff features
functions correctly, please wait 5–10 seconds to engage the trigger
after releasing it.
CARE AND MAINTENANCE
Shutoff and Storage:
1. Power off the unit.
2. Disconnect the spray gun (13) from the hose (18).
3. Pull the spray gun trigger to remove any remaining water.
4. Turn the unit back on and run for approximately 30 seconds.
5. Power off the unit.
6. Disconnect the hose (18) from the unit and drain any remaining water.
7. Drain any remaining water from the water reservoir (3).
8. Place all loose parts into the mesh storage compartment (12).
9. Store the unit indoors at a temperature higher than 32°F.
Storing in Freezing Conditions:
If the unit must be stored in temperatures below 32°F, you can prevent freezing and reduce mineral deposits by using
a pump protector or a non-toxic RV anti-freeze.
NOTE: only use RV anti-freeze. All other anti-freeze products are corrosive and can damage the pump.
1. Pour approximately ½ gal. (3L) of RV anti-freeze into the water reservoir (3).
2. Connect the hose, spray gun, and power cord.
3. Turn the reservoir cover (1) counterclockwise to remove.
4. Point the spray gun into the reservoir and squeeze the trigger for approximately 30 seconds or until anti-freeze
stream
steadies.
5. Toggle the power switch to the “O” position.
6. Pull the trigger to release the pressure.
7. Disconnect the hose, spray gun, and power cord.
8. Place all loose parts in the mesh storage compartment.
Using the Pressure Washer after Storing with Anti-Freeze:
1. Turn the reservoir cover (1) counterclockwise to remove.
2. Drain the anti-freeze from the reservoir.
3. Connect the hose, spray gun, and power cord.
4. Fill the reservoir with clean water and run the unit until the reservoir is empty.
5. Fill with clean water again, and use as usual.