Troubleshooting
5
Distributed by
C&A Marketing, Inc.
114 Tived Lane East
Edison, NJ 08837 USA
Europe: C&A Europe
167 Hermitage Road
Crusader Industrial Estate
London N4 1LZ
United Kingdom
Made in China
Ivation and the Ivation logo are registered
trademarks of C&A Holdings, LLC in the U.S.
©2017 All rights reserved
Customer Service:
[email protected]
866-849-3049
Specifications
Power Supply: 115V/60Hz
Power Consumption: 230W/ 2.5A @ 80˚F, 60% RH; 270W/2.9A @ 86˚F, 80% RH
Dehumidify Capacity: 11Pints/Day @ 80˚F, 60% RH
Reservoir Capacity: 3.5 pints (2L)
Noise: ≤45dB(A)
Air Circulation: 71CFM
Refrigerant / Charge: R134a/3.88 oz. (110g)
Working Temp.: 41°F–95˚F
Recommended Room Size: 160~215 sq. ft.
Timer : 0–24hr
Auto Defrost: Yes
Button: Touch
Dimensions: 10" ×9.6" ×19.5"
Net Weight: 22 lbs.
Problem
Possible Cause
Solution
The unit doesn't operate
No power supply
Connect to a functioning outlet and
switch on
The reservoir is full
Drain the reservoir and make sure it is
securely in place. Then reset the unit
The room temperature is under
41° and the error shows ”CL”
Or the room temperature is
above 95° and the error shows
“CH”
Built in safety features prevent this unit
from operating at these temperatures
Timer function is active
Deactivate timer function
The dehumidifying
function doesn't work or
the unit turns on / off
frequently
The air filter may be clogged
Clean the air filter
The door/window may be open
Close the door/window
The unit may be close to a heat
source
Move the unit to a cool place
The vents may be blocked
Remove the obstruction from the vents
E1 error code
Evaporator sensor problem
Remove the connection mouth and plug
it in again. If this does not solve the
problem, change the sensor.
E2 error code
Humidity sensor problem
Remove the connection mouth and plug
it in again. If this does not solve the
problem, change the sensor.