ThunderION2.0_UM_9752160050_NL_D_GB_F_V1_0
43
GB
4 Technical specifications
Required power supply*
Supply voltage
21–27 V DC
Current consumption
Max. 2 A DC
Standard cable
1
Ω
/10m
Connection
M12 connector, 5-pin
Output
Output voltage
Max. 30 kV positive and negative
Current per emitter to
earth
<150 uA
Environment
Operating environment
Industrial
Ambient temperature
0 – 55°C
Cooling Convection
Operating distance
300 – 1000 mm
Local functions
Indication of pulse
frequency setting
Flashing red and green LEDs during start-up of the bar
[On] signaling
Green LED
[Error] signaling
Red LED lights up in the case of an internal overload or
short circuit.
Red LED flashes when the HV OK output is overloaded
or other errors have been detected (e.g. supply voltage
too low, overheated power supply)
[Warning] signaling
(only IQ version)
Orange LED when Bar needs to be cleaned
Remote functions
(standard version)
Remote On/Off input
Switching high voltage on and off
Control voltage specifications:
10 V DC, 10 mA min.
30 V DC, 25 mA max.
Bar operating OK output
(HV OK)
Remote functions
(IQ version)
Indicates that the bar is operating correctly
(when high voltage is switched on).
Uo= Supply voltage — 1 V, Max. 50 mA
Through the IQ Easy manager the bar can be
monitored and controlled (see manual IQ Easy
manager)
Mechanical
Effective bar length
250 mm to 4750 mm
Dimensions (WxHxL)
61 mm x 114 mm x total length (Eff. 195 mm)
Weight
0.8 kg + 2.4 kg/m
Housing
Emitter
Emitterholder
Plastic
Special alloy
Silicone
Mounting material
Brackets
Summary of Contents for SIMCO ION ThunderION 2.0
Page 11: ...Thu underION2 0_UM_9752160050 0_NL_D_GB_F_ _V1_0 A A Afbeelding Afbeelding 3 4 10 ...
Page 30: ...Thu underION2 0_UM_9752160050 0_NL_D_GB_F_ _V1_0 A A Abbildung Abbildung 3 4 29 D ...
Page 39: ...Thu Ab underION2 0_U bbildung 11 M_9752160050 1 Ersatzte 0_NL_D_GB_F_ eile _V1_0 38 ...
Page 47: ...Thu underION2 0_UM_9752160050 0_NL_D_GB_F_ _V1_0 Figure 3 Figure 4 46 ...
Page 57: ...Thu Fig underION2 0_U gure 11 S M_9752160050 pare Parts 0_NL_D_GB_F_ s _V1_0 56 ...
Page 65: ...Thu underION2 0_UM_9752160050 0_NL_D_GB_F_ _V1_0 Figure 3 Figure 4 64 ...
Page 75: ...Thu Fig underION2 0_U gure 11 P M_9752160050 Pièces de r 0_NL_D_GB_F_ rechange _V1_0 74 ...