22
IQ Power™ BPS
5201197 Rev. D
6. OPERATION
NOTE –
Before switching on power supply; ensure units are properly grounded and
static bar & probes are properly installed.
Power Supply Indicators
Power:
Lights (green) to indicate power is on and the IQ Power™ system is ready to
operate.
Comm:
Lights (green) to indicate digital communication is established with an IQ Power
Communication Module or Control Station. The Comm light will flicker to indicate
communication activity.
Bar On:
Lights (green) when static neutralizing bar is active.
Fault:
Lights (red) to indicate faulty condition of static bar, power supply or high voltage
connections. Power will have to be turned off to clear the fault. When fault is cleared and
power is restored, the fault light will be extinguished.
Clean Bar:
Lights (yellow) to indicate need to clean static bar. Clean Bar indicator may
light with low ion output (dirt build-up on ion emitters) or high output current (conductive
contamination on face of bar). See Maintenance section for static bar cleaning details.
Mode:
The indicator next to the type of bar connected will light (green). “Speed”,
“Hybrid” or “Distance” will be indicated.
In cases where two different types of bars are connected, the system will set for the safer
of the two operating voltages and light the corresponding Mode indicator.
The Output indicators (along with the Mode indicators) indicate the
Power Supply
number
during start-up of the power supply.
Output:
The output indicators range from “Low” to “High” in 10 steps (2-red, 3-yellow,
5-green) and light to indicate the system relative ion output. The output will normally be
in the high range. Low output generally indicates the need to clean the static bar. See
Maintenance section for static bar cleaning details.
Power Supply Operators
Calibrate:
Is a momentary push button switch located on the face label. Pressing the face
label firmly on “Calibrate” initiates the calibration sequence and sets the relative nominal
ion output for the system.