Appliances with Flammable Refrigerants
keep all Ventalation openings in the appliance and in the structue of the building clear at all times.
Do not use any mechanical devices or any other means to accelerate the defrosting process, other than those
recommended by the manufacturer.
WARNING:-
In order to reduce flammablity hazards the installion of this appliance must only be carried out by a suitably qualified
engineer.
Loading and Airflow
Ensure that there is no more than 75kg for a CT75 of evenly distribute product placed on the ten shelves and for the
CT105 it is 105kg of evenly distribute product placed on the ten shelves.
Always ensure the air can circulate around/through the stored product.
It is important that for optimal energy performance that adequate airflow is maintained around the perimeter of the
shelves, and around all stored products.
On all models please ensure that no product is placed on the unit base.
Clearance (All models)
Make sure that a minimum clearance of 310mm above and 50mm around the cabinet or
counter is available for ventilation and effective operation.
Cleaning
Important: Before cleaning, the unit should be put into standby and then the power supply should be turned off at the
mains.
Please do not plug or unplug the unit with wet hands.
Only when cleaning has been completed and the unit is dry should the cabinet be turned back on at the mains.
Suitable P.P.E (Personal Protective Equipment) should be worn at all times.
•
All gaskets should be inspected on a regular basis and replaced if damaged. To clean, wipe with a warm damp
soapy cloth followed by a clean damp cloth. Finally thoroughly dry.
Condenser Cleaning
•
Maintenance should take place on a regular basis or as and when required by a competent/trained personnel
Traditional
Fin Coil
If there are any stubborn grease deposits left on or through the condenser call your supplier to carry out a full service
(this is normally chargeable). Failure to maintain the condenser may invalidate the warranty of the condensing unit
and cause premature failure of the motor/compressor. Do not use a wire brush to clean the condenser.
Traditional Fin Condenser Coil
2
Summary of Contents for Foster Control Thaw CT105
Page 6: ...English Switching to Run Switching to Standby 5 ...
Page 8: ...English Cancelling a Thaw Program How to Get A Thaw Program Information 7 ...
Page 9: ...English User Program Adjustment 8 ...
Page 10: ...English Active Alarms Warning and Alarms 9 ...