18
Integrated Technical Vision Ltd
http://www.itvsystems.com.ua
For example number 235 is displayed as follows:
2 blinks, pause, 3 blinks, pause, 5 blinks. Zero is signalled by one long Buzzer sound
and LED2 flashing. For example 040 will be reflected by 1 long flashing, pause, 4
blinks, pause, 1 long flashing.
Code settings are reflected by LEDs 2 and 3 blinks.
Programming via PC
DLK642 Lite panel can be connected to PC using interface converter NTC LNET or
NTC LNET Lite that allows easy autonomous mode programming. For the detailed
information turn to software user manual.
Programming via built-in keyboard
The panel cannot switch to programming mode if it is in main mode, resistor load
should be connected to all used outputs.
In order to turn the panel to the programming mode, enter engineer or master
code on keyboard
[engineer code] [#]
OR
[master code] [#]
. You will hear
several short sound signals and see all LEDs blink, then LEDs 1 and 2 blink
alternately and LED 3 is off. Factory defaults are: engineer code [1234], and
master code [5678].
Engineer and master code should be changed during programming. Code length
should not be less than four digits.
Invalid code or false command entry are indicated by long sound signal of the
buzzer and LED 1 red and LED 3 green flashing.
The panel ignores RTE button contact break/shortage in any programming mode.
Control panel programming diagram is enclosed in Appendix section.
Factory defaults
The panel switches to main day mode when first engaging or resetting to factory
defaults with the following settings:
- Keyboard blocking time - 40sec.
- Engineer code [1] [2] [3] [4].
- Master code [5] [6] [7] [8.].
- Internal reader works only.
- Relay 1 runs door B locking device, works in impulse mode, locking
device time is 1sec.
- Relay 2 runs bell, works in the impulse mode, time is 5 sec.
- First transistor output (SA contact) is programmed for alarm.
- Second transistor output (BEL contact) is not used.
- Single one-sided door (B) is used only.
- Cord 1 is used as door B contact sensor.
- Cord 2 is used as door B RTE button.
- Cord 3 is used as door B fire alarm input (free pass).
- Cord 4 is used as door B blocking input.
- Cords 5-8 are not used
Programming the panel in stand-alone use