INSTALLATION MANUAL SCALA 3000
ADVICE FOR THE INSTALLATION OF SCALA 3000 COMPACT
STEP 1: LOCATION OF THE ICE MACHINE
•
Needs an electricity commenction: 1 three phase socket 5+TTx6 mm2. Install differential
and thermal in the main frame (32 amps, consumption 14870W).
•
Water supply: needs a nearby tap for water inlet. ¾”.
•
Outlet: The unit has an overflow tube, to prevent water from entering the evaporator
drum, in the event of failure of the filling buoy. Needs to have an outlet drain nearby.
The drain pipes of the unit should not be siphoned at any time, the water should drain
without problems. In addition, there is a shut-off valve with tap for emptying the water
tank. 21 mm diameter or 38 mm diameter depending on the unit.
•
The machinery must be hoisted with care not to move the gear motor on the
evaporator. Use a lift or crane with straps using the unit's base.
•
Keep in mind that the air enters through the condenser front and exits to the area of
the compressor. Have good ventilation in the location of the unit.
•
Level the unit correctly.
Minimum value
Maximum value
Room temperature
5º
40º
Water temperature
5º
35º
Water pressure
1 bar
5 bar
Voltage variation
-10%
6%