background image

 MS ICE MAKER MAINTANEANCE

 

 
 

1.  AIR CONDENSER CLEANING: 

 

1. 

Disconnect the unit from the electricity. 

2. 

Clean condenser using a vacuum cleaner, soft brush or low pressure air. Clean 
from top to bottom, not side to side. Be careful not to bend the condenser fins. 

3. 

Connect the unit to the electricity. 
 
 

2.  WATER CIRCUIT CLEANING:  

 

1. 

Disconnect the unit from the electricity. 

2. 

Closet the inlet water faucet. 

3. 

Disconnect the condenser water inlet and outlet . 

4. 

Prepare the cleaning product

 Calklin

 or a  solution  with  50%  phosphoric  acid  

and  distilled water.  

Do  not  use  hydrochloric  acid

. We recommend using 

the  cleaning  product  Calklin.   The mixture  is    more    effective    if the    water    is 
between  95ºF and  104ºF. Flow the solution through the condenser for about 
10 minutes using a recirculating pump. 

5. 

Empty the product from the condenser and connect the condenser water intlet 
and outlet.  

6. 

Open the water faucet. 
Connect the unit to the electricity. 
 

3.  WATER FILTER REPLACE 

 

1. 

Disconnect the unit from the electricity. 

2. 

Closet the inlet water faucet. 

3. 

Close de faucets before and after the filter. 

4. 

Remove the old cartridge and replace it with a new one. 

5. 

Open all the closed faucets. 

6. 

Connect the unit to the electricity. 
 
 

4.  WATER CIRCUIT CLEANING:  

 

1. 

Remove the top cover screws to remove the cover. 

 
 

 

 
 
 
 
 
 
 

Summary of Contents for MS Series

Page 1: ...ater Do not use hydrochloric acid We recommend using the cleaning product Calklin The mixture is more effective if the water is between 95ºF and 104ºF Flow the solution through the condenser for about 10 minutes using a recirculating pump 5 Empty the product from the condenser and connect the condenser water intlet and outlet 6 Open the water faucet Connect the unit to the electricity 3 WATER FILT...

Page 2: ...lime Do not use hydrochloric acid We recommend the use of any NSF approved scale removal product In modular machines the water bucket is filled automatically so we recommend to prepare a previous solution for example 0 15 gal according to the manufacturer s instructions with the total quantity of product needed for the water tray 0 8 gal for MS 500 and 1 6 gal for MS 1000 and 0 9 gal for MS 700 To...

Page 3: ...over and residue move the ice wash switch to the WASH the machine will drain the reservoir and refill it and then set the ice wash switch to the OFF position 7 Disconnect power and close water supply 8 Mix a cleaning solution 9 Remove shield and water tray Water level sensor Thickness sensor Ice wash switch Shield Water tray MS 700 Curtain Water level sensor Water tray Thickness sensor Ice wash sw...

Page 4: ...old bleach 12 5 oz gal 0 16 0 133 gr L 1 2 12 5 15 dis 15 add to bleach 14 Sanitize all surfaces of the ice thickness sensor water level sensor shield and water tray applying liberally the sanitizer solution using a cloth or sponge 15 Sanitize the interior surfaces of the freezing compartment including walls plastic parts of the evaporator distributor and the front panel applying liberally the san...

Page 5: ...ests 1 1 Cleaning the bins for undercounter models 1 Disconnect the machine close water faucet and empty storage bin of ice 2 Use the cleaner water solution to clean all surfaces of the bin Use a nylon brush or cloth Then rinse all areas thoroughly with clean water 3 Use the sanitizer water solution to sanitize all surfaces of the bin Use a nylon brush or cloth 4 Rinse with plenty of water dry run...

Reviews: