MS ICE MAKER MAINTANEANCE
1. AIR CONDENSER CLEANING:
1.
Disconnect the unit from the electricity.
2.
Clean condenser using a vacuum cleaner, soft brush or low pressure air. Clean
from top to bottom, not side to side. Be careful not to bend the condenser fins.
3.
Connect the unit to the electricity.
2. WATER CIRCUIT CLEANING:
1.
Disconnect the unit from the electricity.
2.
Closet the inlet water faucet.
3.
Disconnect the condenser water inlet and outlet .
4.
Prepare the cleaning product
Calklin
or a solution with 50% phosphoric acid
and distilled water.
Do not use hydrochloric acid
. We recommend using
the cleaning product Calklin. The mixture is more effective if the water is
between 95ºF and 104ºF. Flow the solution through the condenser for about
10 minutes using a recirculating pump.
5.
Empty the product from the condenser and connect the condenser water intlet
and outlet.
6.
Open the water faucet.
Connect the unit to the electricity.
3. WATER FILTER REPLACE
1.
Disconnect the unit from the electricity.
2.
Closet the inlet water faucet.
3.
Close de faucets before and after the filter.
4.
Remove the old cartridge and replace it with a new one.
5.
Open all the closed faucets.
6.
Connect the unit to the electricity.
4. WATER CIRCUIT CLEANING:
1.
Remove the top cover screws to remove the cover.