background image

ICE QUEEN MAINTENANCE

 

 
 

 

1.

 

AIR CONDENSER CLEANING: 
 

1.

 

Disconnect the unit from the electricity. 

2.

 

Closet the inlet water faucet. 

3.

 

Clean  condenser  using  a  vacuum  cleaner,  soft  brush  or  low  pressure  air.  Clean  from 
top to bottom, not side to side. Be careful not to bend the condenser fins. 

4.

 

Open the inlet water faucet. 

5.

 

Connect the unit to the electricity. 
 

2.

 

WATER FILTER REPLACE 
 

1.

 

Disconnect the unit from the electricity. 

2.

 

Closet the inlet water faucet. 

3.

 

Close de faucets before and after the filter. 

4.

 

Remove the old cartridge and replace it with a new one. 

5.

 

Open all the closed faucets. 

6.

 

Connect the unit to the electricity. 
 

3.

 

WATER CONDENSER CLEANING:  
 

1.

 

Disconnect the unit from the electricity. 

2.

 

Closet the inlet water faucet. 

3.

 

Disconnect the condenser water inlet and outlet . 

4.

 

Prepare  a  solution  with  50%  phosphoric  acid  and  distilled water.   Do  not  use  
hydrochloric  acid
. We recommend using the cleaning product Calklin.  The mixture is  
more  effective  if the  water  is between  35ºC and  40ºC. Flow the solution through 
the condenser for about 10 minutes using a recirculating pump. 

5.

 

Empty  the  product  from  the  condenser  and  connect  the  condenser  water  intlet  and 
outlet.  

6.

 

Open the water faucet. 

7.

 

Connect the unit to the electricity.  
 

4.

 

WATER CIRCUIT CLEANING:  
 
WARNING: Do not use the ice made during the first 5 minutes.
 
 

8.

 

Unplug the machine from the electricity 

9.

 

Close the water inlet faucet. 

10.

 

Modular machines: Disconnect the compressor directly from the contactor on the 
electric box. Compact machines: 50 and 85, place the cleaning switch on 0 to stop the 
compressor. 

 