ICE QUEEN MAINTENANCE
1.
AIR CONDENSER CLEANING:
1.
Disconnect the unit from the electricity.
2.
Closet the inlet water faucet.
3.
Clean condenser using a vacuum cleaner, soft brush or low pressure air. Clean from
top to bottom, not side to side. Be careful not to bend the condenser fins.
4.
Open the inlet water faucet.
5.
Connect the unit to the electricity.
2.
WATER FILTER REPLACE
1.
Disconnect the unit from the electricity.
2.
Closet the inlet water faucet.
3.
Close de faucets before and after the filter.
4.
Remove the old cartridge and replace it with a new one.
5.
Open all the closed faucets.
6.
Connect the unit to the electricity.
3.
WATER CONDENSER CLEANING:
1.
Disconnect the unit from the electricity.
2.
Closet the inlet water faucet.
3.
Disconnect the condenser water inlet and outlet .
4.
Prepare a solution with 50% phosphoric acid and distilled water. Do not use
hydrochloric acid. We recommend using the cleaning product Calklin. The mixture is
more effective if the water is between 35ºC and 40ºC. Flow the solution through
the condenser for about 10 minutes using a recirculating pump.
5.
Empty the product from the condenser and connect the condenser water intlet and
outlet.
6.
Open the water faucet.
7.
Connect the unit to the electricity.
4.
WATER CIRCUIT CLEANING:
WARNING: Do not use the ice made during the first 5 minutes.
8.
Unplug the machine from the electricity
9.
Close the water inlet faucet.
10.
Modular machines: Disconnect the compressor directly from the contactor on the
electric box. Compact machines: 50 and 85, place the cleaning switch on 0 to stop the
compressor.