Operating Instruction Jumper Cable Rev. -
Page
21
of
27
Description
Value
Applied standard
GB-T 20234
Charging mode
Mode 2 & 3B (IEC 61851)
Max. operating temperature
+50 °C
Min. operating temperature
-30 °C
Max. operating voltage
250 V-AC (Single phase)
440 V-AC (Three phase)
Rated current
10 A, 16 A, 32 A
Max. application height above sea level
2000 m
Degree of protection
IP54 / IP55
CONNECTOR MARKING
Item
Designation
Item
Designation
1
L1 (Line 1)
8
Connection Cable
2
CC (Proximity)
9
L1 (Line 1)
3
CP (Control Pilot)
10
CS/CC/PP (Proximity)
4
N (Neutral)
11
CP (Control Pilot)
5
L2 (Line 2) for 3Phase only
12
N (Neutral)
6, 14
PE
13
L2 (Line 2) for 3Phase only
7
L3 (Line 3) for 3Phase only
15
L3 (Line 3) for 3Phase only
Table 17: Contact arrangement for GBCE & GBCV Jumper Cable
Figure 13: Connector Overview, left side: GBCE (Plug); right side: GBCV (Connector)
Table 16: Specifications for GBCE & GBCV Jumper Cable
8
1
2
3
4
5
6
7
9
10
11
12
13
14
15
EXPORT CODE C
COMMERCIAL. RESTRICTED TO EMBARGOED COUNTRIES AND DENIED PARTIES.