UltraCirc Models

The BU models incorporate a shut off valve, check valve, and bleed valve  into the brass pump housing eliminating the 

need to install these components. These models are supplied with 1/2” (5/8”) union fittings. These fittings should be 

removed from the pump housing before soldering to avoid damaging the internal valves.

8. Close the shut-off valve on the inlet side of the pump and turn the water supply to the house back on.

9. Flush system of debris.

Before reattaching the pump motor, open the shut-off valve on the inlet side of the pump housing and let water flow 

through the housing. Use a bucket to catch the water. Let the water run long enough to clear all sand, solder pellets, 

plumbers tape flakes, etc. from the lines. Close the inlet shut-off valve when finished.

10. Connect the pump motor to the housing.

Make sure the rubber o-ring is in place in the housing and the screw ring is securely hand tightened. Reopen the shut-

off valve or valves and let the water flood the pump housing.

Do’s and Do Not’s

Do

•  Install an air vent mounted in a vertical position (if provided).

•  Use 1/2”(5/8”) recirculation line tubing.

•  Check to be sure there are no crimps or sharp bends in the recirculation line that would restrict the flow.

•  Be sure the check valve is installed in the proper direction of the flow.

•  Be sure all air is purged from the system prior to starting the pump.

•  Use a water conditioner if you have hard water.

•  Be sure the gate valves are open before turning on the pump.

•  Install the pump pumping in upward direction only.

Do Not

•  Use grease or oil to lubricate the pump (it is self-lubricating).

•  Over tighten the screw ring.

•  Install the pump with the motor above the pump housing.

•  Install the pump pumping away from the water heater nor pumping downward.

•  Start the pump before the system is full of water and purged of air.

•  Allow the water heater temperature above 140ºF (60ºC). (only in the US)

•  Install the pump in the supply line to faucet/taps.

•  Use any pipe size other than 1/2”(5/8”) for all models.

•  Position the pump at the top of the water heater.

Correct Installation

Improper Installation - 

Do NOT mount in these orientations

Note: Keep The Hot Water 

Temperature  Below  140ºF 

(60ºC).  Higher  temperatures 

can cause calcium and 

magnesium elements to come 

out of solution and create 

solids  which  could  not  only 

cause damage to the pump but 

also reduce water heater 

efficiency and premature 

failure of the water heater.

fig. 6

Remove the motor unit and 

o-ring from the pump housing into the plumbing 

line.  Do not sweat the housing into the plumbing 

line with the motor or o-ring attached. Arrows on 

the pump housing indicate the direction of water 

flow.

Caution: Only hand tighten the screw ring. 

Do not over tighten! Do not use plumbers 

putty on the screw ring.

11. Purge air from the supply line.

Turn on the faucet/taps or shower farthest from the water heater. Open the line until you get a good, steady stream of 

water without sputter or evidence of air.

12. Purge air from the return line.

Connect the pump to the electrical supply. With the pump running, open the hose bib/connection and let water run 

until the pump is running quietly and there is no sputtering or other evidence of air coming from the hose bib. Close 

the hose bib. Your system is now in operation. Allow a few minutes for instant hot water to recirculate to all of your 

faucet/taps.

8. Install the pump and other components required in accordance with the diagrams provided in fig. 1 or 2 and 

connect the return line to the water heater. 

Unscrew the pump housing from the motor (fig. 6) and run the pump 

for a few seconds to make sure it is operational. 

Summary of Contents for Laing Thermotech E1 Series

Page 1: ...ump The pump only has to produce continuous flow at a pressure sufficient to overcome the friction losses created by the piping in the house water supply line and the return line Oversized Pumps Pumps should not be so large as to produce flow rates that may eventually erode holes in the pipes According to the Copper Development Association excessive erosion occurs at a velocity of about 5ft 1 5m p...

Page 2: ...han 10º F 6º C below the Set Point The adjustable thermostat is only available on fixed speed motors 2 Plan your installation Decide on the course of the recirculation pipe also determining the length of the pipe required and whether the return line should be connected to the water heater cold water inlet line tee fitting required or to the bottom water heater drain valve Y type fitting required t...

Page 3: ...ble for at least 221ºF 105ºC F Laing circulators are thermally protected and do not require external overload protection G If a remote device such as a thermostat aquastat is connected to the pump it must be wired in series with the power conductor 4 Purchase materials required Laing e3 ReCirc 1 1 2 5 8 or 3 4 swing check valve Copper pipe or tubing not required on BU models Tee for under sink con...

Page 4: ...mp pumping away from the water heater nor pumping downward Start the pump before the system is full of water and purged of air Allow the water heater temperature above 140ºF 60ºC only in the US Install the pump in the supply line to faucet taps Use any pipe size other than 1 2 5 8 for all models Position the pump at the top of the water heater Correct Installation Improper Installation Do NOT moun...

Page 5: ...ng causing the rotor to wobble during operation If the return line connects to the cold water supply at the top of water heater the warm water may be creating back pressure in the cold supply line If so add a check valve non return valve on the cold supply line above the return line tee connector Pump Operating Intermittently or Not at All No power to the pump There is debris or foreign matter in ...

Page 6: ...the motor leads before continuing Failure to follow these instructions could result in serious personal injury death and or property damage WARNING High Pressure Hazard Pressure may be present in the pump body This pressure can be relieved by loosening the flange bolts and shifting the pump assembly slightly to allow the pressurized water to escape Failure to follow these instructions could result...

Reviews: