Table 2: Impeller Shim Thickness
Impeller Diameter (inches)
Measure Clearance Minus Shim Thickness (in-
ches)
up to 11
.010 to .015
11 to 14
.015 to .020
over 14
.020 to .025
NOTICE:
•
For 360TY with 320TY mounting flange motors only, delete impeller washer (199) and
impeller screw (370C) and replace with impeller nut (304) of 316SS for all pump con-
structions.
•
Flat head screws (372J) furnished instead of hex cap screw (370J) on 3" JCU with
210TYZB motor.
•
Threaded hardware coated with Loctite 242, or equal. When impeller nut is used, Loc-
tite 272 with primer should be used.
Table 3: Impeller hardware torque values
Motor Frame
Impeller Mounting Hardware
Required Torque, Lubricated (ft/
lbs)
180TY
1/2"-13 UNC bolt w/washer
27
210TYZ
5/8"-11 UNC bolt w/washer
54
250TY
5/8"-11 UNC bolt w/washer
54
320TY
3/4"-10 UNC bolt w/washer
66
360TY
1-1/2"-12 UNF nut
623
NOTICE:
1.
Loctite 242 shall be applied to impeller bolt prior to each assembly. When impeller nut
is used, Loctite 272 with primer should be applied. Refer to Loctite for thread-lock appli-
cation instructions.
2.
Impeller mounting hardware is designed for one time use only. New hardware shall be
installed during each assembly.
3.
Torques in this table are based on a 416 stainless steel motor shaft material and
bolt/nut materials of SAE F593 Groups 1 & 2. For other material combinations, refer to
factory for torque value.
5.4 Reassembly
22
JCU Installation, Operation, and Maintenance Manual
Summary of Contents for GOULDS PUMPS JCU
Page 1: ...Installation Operation and Maintenance Manual JCU ...
Page 2: ......