With temperatures up to 280° C oil bath lubrication has to be used
Temperature classes
Refer to Temperature limits
NOTICE:
Consult the manufacturer for higher pressures and lower or higher temperatures.
Sizes
Group 1
Group 2.1
Group 2.2
40-25-160
100-65-160
40-25-250
50-32-160
125-80-160
50-32-250
65-40-160
100-65-200
65-40-250
80-50-160
125-80-200
80-50-250
40-25-200
125-100-200
100-65-250
50-32-200
125-80-250
65-40-200
50-32-315
80-50-200
65-40-315
80-50-315
*1
Low-Flow sizes : not included in ISO 2858 / DIN EN 22858 not as model ICMP
Designation codes
Im
p
el
le
r
C
a
si
n
g
P
la
in
b
ea
ri
ng
P
la
in
b
e
a
ri
ng
C
a
n
M
a
gn
et
s
C
o
u
p
lin
g
si
ze
ICM 80-50-200 N L L C C N 025
B
P
I
Frame mounted
Close-coupled
Process pump
Inducer
SSiC
DRYGUARD
S
C
High temperature
Low temperature
H
L
Hastelloy C
NdFeB
SmCo
S
N
Nm
Ductile cast iron
Cast iron
Cast steel
Stainless steel
Duplex SS
Hastelloy C
Titanium
F
V
W
C
T
L
V
W
C
T
N
standard
2.2 Intended use
The pump is equipped with a permanent-magnet synchronous drive. It is suitable for the leak-free con-
veyance of aggressive, toxic, ignitable or hot liquids
2.2 Intended use
Model ICM/ICMP Magnetic Drive Chemical Process Pump with Grease Bearing Lubrication Installation, Operation, and
Maintenance Manual
11
Summary of Contents for Goulds Pumps ICM
Page 2: ......