7.1.12 Removal of Stub Shaft
1.
Loosen screws (920.41) and pull motor with stub shaft (210) out of the motor lantern (341).
2.
Loosen radial stub shaft screwing (904.41 and 904.42) (stud bolts) and deduct stub shaft (210) from
motor shaft. For support (break loose) you can insert a solid screw driver into the cross boring,
press it against the front face of the motor and move both shafts against each other.
7.1.13 Preassembly inspections
7.1.13.1 Reconditioning
After disassembly all parts must be cleaned and checked for wear carefully. Worn or damaged parts
must be replaced by new parts (spare parts).
It is recommended in most cases to replace mechanical seal, ball bearings and seals (flat seal, O-rings).
NOTICE:
All PTFE sealing elements and graphite seals are intended for being used only once.
In most cases it make sense, if damaged absolutely necessary, to renew the mechanical seal and the
bearings Deposits on the impeller (230), in the volute casing (102V) or on the casing cover must be re-
moved.
Clearance at impeller
Suction side of impeller shown below left, back vanes of impeller shown below right
Figure 10: Suction side of impeller (shown on left), Back vanes of impeller (shown on right)
100-65-315
125-80-315
125-100-315
150-125-315
Figure 11: Drive side of impeller (only with pump size shown below)
Nominal diameter D (mm)
60
68
85
100
120
135
155
175
220
7.1 Maintenance