background image

Page 7 of 8

 

GB50-IOM Rev. 0    8/20 

                             

 

THIS INFORMATION IS SUBJECT TO THE CONTROLS OF THE EXPORT ADMINISTRATION REGULATIONS (EAR).  THIS INFORMATION SHALL NOT BE PROVIDED TO 
NON-US PERSONS OR TRANSFERRED BY ANY MEANS TO ANY LOCATION OUTSIDE THE UNITED STATES CONTRARY TO THE REQUIREMENTS OF THE EAR. 

GB51XC/GB53XW SERIES

 

 

GB51XC/GB53XC SERIES

         

 

             

 

 

MODEL BORE A 

E  F G  H  J  K  L  M 

STROKE 

GB51

 

GB51XC3 

4” 

5-1/4” 

7-1/16 5” 16-5/8” 

5/8-18 

 

3/8” 13/32”  2-3/4” 

- - - 

6” 

3” 

GB51CX4 8-1/16 

6” 

18-5/8” 

4” 

GB51XCA3 7-1/16 

11-5/8” 

3/8-16 1/2” 3-1/4” 

3” 

GB51XCA4 8-1/16 

12-5/8” 

4” 

GB51XW3 

5” 

7-1/2 5” 12-1/2” 

3/8” 13/32”  2-3/4” 

- - - 

3” 

GB51XW4 8-1/2 

6” 

14-1/2” 

4” 

GB51XWA3 7-1/2 

3/8-16 1/2” 3-1/4” 

3” 

GB51XWA4 8-1/2 

4” 

GB52

 

GB52XC11/8 

6” 

7-3/16” 

5-1/16” 3-5/16” 

12-15/16” 

3/4-16 

1/2” 17/32”  3-3/4” 

- - - 7” 

1-1/8” 

GB52XC4 8-3/8” 

6” 

18-15/16” 

8-1/2” 

4” 

GB52XC6 11-1/8” 

8” 

23-11/16” 

6” 

GB52XA118 5-1/16” 

9-5/8” 

1/2-13 13/16” 4-1/2” 

1-1/8” 

GB52XA4 8-3/8” 

12-15/16” 

4” 

GB52XA6 11-1/8” 

15-11/16” 

6” 

GB52XW118 

7” 

5-1/2” 3-5/16” 

8-13/16” 

1/2” 17/32”  3-3/4” 

- - - 

1-1/8” 

GB52XW4 8-15/16” 

6” 

14-15/16” 

4” 

GB52XW6 11-9/16” 

8” 

19-9/16” 

6” 

GB52XWA118 5-1/2” 

1/2-13 13/16” 4-1/2” 

1-1/8” 

GB52XWA4 8-15/16” 

4” 

GB52XWA6 11-9/16” 

6” 

 
 
 
 
 

Summary of Contents for Conoflow GB50 Series

Page 1: ...input to the connection marked INST on the positioner Then connect a supply of clean filtered air to the supply connection port to supply both the positioner and the cushion loading device The supply...

Page 2: ...positioner from the head plate GB50 Remove the set screws and lift out the cylinder head plate GB51 55 Remove the cover Spirolox type retaining ring and lift out the cylinder head plate Disconnect th...

Page 3: ...or Positioner V GC34 Commandaire Positioner with Cushion Load Regulator F GC31 Commandaire Positioner with full reversal GH232T Reversing Relay and GFX04 Supply Filter G GC33 Commandaire Positioner wi...

Page 4: ...TSIDE THE UNITED STATES CONTRARY TO THE REQUIREMENTS OF THE EAR FIGURE 1 GB50 SERIES ACTUATOR LABELED SECTION VIEW SHOWING CURRENT PISTON SEAL GB50 SIZE FIGURE 2 GB51 53 SERIES ACTUATOR LABELED SECTIO...

Page 5: ...E CONTROLS OF THE EXPORT ADMINISTRATION REGULATIONS EAR THIS INFORMATION SHALL NOT BE PROVIDED TO NON US PERSONS OR TRANSFERRED BY ANY MEANS TO ANY LOCATION OUTSIDE THE UNITED STATES CONTRARY TO THE R...

Page 6: ...D E F G H J K L M STROKE GB50XC2 3 3 1 2 6 1 8 3 3 4 13 15 16 1 2 20 5 16 11 32 2 3 4 5 1 4 2 GB50XC5 9 1 8 6 3 4 19 15 16 5 GB50XC8 12 1 8 9 3 4 25 15 16 8 GB50XCA2 6 1 8 10 3 16 5 16 18 1 2 2 3 4 2...

Page 7: ...1CX4 8 1 16 6 18 5 8 4 GB51XCA3 7 1 16 11 5 8 3 8 16 1 2 3 1 4 3 GB51XCA4 8 1 16 12 5 8 4 GB51XW3 5 7 1 2 5 12 1 2 3 8 13 32 2 3 4 3 GB51XW4 8 1 2 6 14 1 2 4 GB51XWA3 7 1 2 3 8 16 1 2 3 1 4 3 GB51XWA4...

Page 8: ...8 4 10 3 8 1 2 17 32 3 3 4 9 1 2 1 1 2 GB53XW4 9 17 32 6 15 7 32 11 3 4 4 GB53XW6 11 25 32 8 19 25 32 11 3 4 6 GB53XW8 13 25 32 10 23 25 32 14 1 2 8 GB53XW10 15 25 32 12 27 25 32 14 1 2 10 GB53XWA112...

Reviews: