background image

TCI Library- http://www.telephonecollectors.info/

Summary of Contents for 584C

Page 1: ...n in a key telephone installation 1 02 This section supersedes KSP584 102 and all previous documents covering the 584C 13 card panel Whenever this section is reissued the reason for reissue will be listed in this paragraph 1 03 This equipment can be configured for use with dial pulse or DTMF dual tone multifrequency telephones The equipment has been granted an FCC registration number under Part 68...

Page 2: ...e card mounting assembly with machine screws inserted CABLE CONNECTORS through elongated holes When the screws are loose the bracket can be slid from side to side To lock the KTUs in place the bracket is slid to the left and the screws are tightened TERMINAL PANEL ASSEMBLY 2 06 The terminal panel assembly makes up the back of the 584C card panel It is equipped with three 25 pair male connectors an...

Page 3: ...he 21 pin receptacle on the card mounting assembly The interrupter operates from 10 volts 60 Hz AC from the key system power supply It pro duces a 15 IPM signal for interrupted ringing a 60 1PM lamp flash signal and a 120 IPM lamp wink signal One interrupter can be used to provide the interrupted ringing lamp flash and lamp wink signals for one or two 584C card panels ISS 1 SECTION 36 584 101 CHAS...

Page 4: ...L YL SL Y L SL YL S L SL Y L SL YL SLYL CO or V I BL CO or T VI BL VIB L PB X BL V I PBX R BL V I BL V I V I OR T VI OR V I OR LINE OR VI LINE R OR VI OR V I 5 V I GN 10 A VI GN V I GN GN V I GN V I GN VI VI BN VI BN VI BN BN VI SN VI BN VI VI SL VI SL VI SL SL VI SL VI SL VI AW 84 82 Figure 3 Arrangement of Key System Connecting Blocks ner connect the second cable from connector 2 to connecting b...

Page 5: ...phone or one IO button telephone One 50 pair block can serve two 6 button or IO button telephones or one 20 button telephone ISS 1 SECTION 36 584 101 POWER SUPPLY PANEL PANEL W INTERRUPTER W 0 INTERRUPTER AGND 5 5 A BA rT 24 VDC Filtered 7 7 B GND 3 3 B BATT 1 24 VOCI Ringing GNO __ 40 40 Ringing Voltage 105 VACI 43 43 GND __ 16 16 10 VAC Lamps 9 18 GND 20 20 10 VAC Lamps __ 18 Motor GND 26 26 Mot...

Page 6: ...KTU 10 BUTTON STATION 20 BUTTON STATION c r c l c J STANDARD COLOR CODE Figure 6 Typical Station Block Layouts each KTU as detailed in the following paragraphs Use standard one pair and three pair cross connect wire 3 14 One line card KTU 400E or equivalent is required for each CO or PBX line serving the system Strap each line card for the required options then insert each card into the desired KT...

Page 7: ...ck Use bridge clips to complete the connec tions to the single line telephone Refer to Figure 8 Note In systems using 400TPL or 400PFL line card KTUs single line telephones used as CO PBX line answering stations will not ring unless connected via a 346A KTU ISS 1 SECTION 36 584 101 CON NECTI NG BLOCK A CR OSS CONNECT WIR E MISC CONN ECTI NG BLOCK QUAD WIR E BR IDGE CLIPS Figure 8 Connecting Detail...

Page 8: ... not necessary to connect buzzer ground since the ground is common via the A1 lead BUTTON ACCESS PAGING 3 18 The 401B manual intercom KTU can also be used for button access to a PA system for voice paging For such applications insert the 401B Pages KTU into an unused KTU card connector on the 584C card panel then arrange the equipment as follows a On connecting block C locate the terminal correspo...

Page 9: ...y be connected in parallel across the circuit Maximum loop resistance is 1200 ohms If Tel Touch telephones are used loop resistance is limited to 500 ohms 3 21 In a key system not equipped with a dial intercom install the 346A KTU as follows for a CO PBX line station a Insert the 346A KTU into any unused card connector on the 584C card panel ISS 1 SECTION 36 584 101 b On connecting block C locate ...

Page 10: ...ls associated with the card connector for the 415A KTU Referring to Figure 14 connect these terminals as follows 1 Connect the COT and COR terminals to the Tip and Ring terminals on the CO con necting block for cross connection to the distant office Use bridge clips to complete the connections Page 10 8Ri0C E CLIPS CO N ECTING BLOCK B SEliCTEO LI NE KE TERMI NAL S ON STATION 8 L0CKS Y L SL SL YL P...

Page 11: ... K i 21 __ 21 _ 1 6 ___ Y L 15 11 LW4 OR GN l __O_R_ _R_ D 7 R l J v 34 TO KGA OR BK 1B 3 z 2 1 KTS 9 v J YL OR _ ____ _ _ _ _ _ R D 13 9 _______ B K 7 RD 12 BL L 10 _ L F3 ___B_L __ t 17 LF4 BL LW3 YL Lil 4 YL OR 6 6 6 37 _ 0 J 9 MB WH 1 5AMP I 2 YL 5 ks ks Ji 1 ___ _ J 43 2 I 44 4 I MG ____________ 28 BN 11 K11 k11 2 x 7 L 42 18 19 LS1 YL 10 VAC GN f c 6 o s 14 F8 15 LS3 BL 10 VAC OR l r 7 17 4 ...

Page 12: ... 49 24 50 25 26 1 27 2 28 3 44 19 45 20 46 2 1 47 22 48 2s 27 AO OR OR AO RO GN l lN RD RO BN AD SL 7 R6 BK BL iir si BK OR OR SK BK GN GNTK BK SN SN BK S L BK Yl BL BL Y L YL 98 O A Y l YL GN GN YL v i TN BN7L YL S L svi VI BL BL VI VI OR QR Y Vl GN GNVi vr iN BNVi VI SL SL VI GN YL Y L SN WH BL BL w H WH OR OR WH 2 __ 28 _ WH GN 3 GN WH 29 WH BN 4 BN WH 30 W l MtL 5 SL WH 31 AD BL s BL RD 32 RO ...

Reviews: