ITS Partner O.B.S S.L · Av. Cerdanyola 79-81 Local C
08172 Sant Cugat del Vallés · Barcelona (Spain)
Phone: +34935839543 · [email protected] · www.ek.plus
CM 8SH-TC
USER MANUAL
INSTALLATION AND WIRING:
General installation and wiring:
1.- For installations of several modules (head-end) or a
single module, mount the transmodulator module to a
wall chassis (
To do this, mount the supplied metal piece (COD:
251008) on the upper rear part of the module as shown
in the image.
Important note: If installing a head-end with several modules, always place the power
supply to the left of the modules to be installed.
2.- Connect the power supply (
) to the module or
connect it to the previous module using the supplied
power cable.
, power supply can also be
used to power a single module.
3.- Connect the input signals to the transmodulator inputs.
Important note: Pay particular attention to the input type and port. Follow the instructions
on the front panel.
4.-
Install the “CM Management” software on the PC. It can be downloaded from the website
Software / CM Head-ends Section.
5.- To program the module, perform out any of the following connections:
5a.- PC
–
FA 524 programming via USB. Connect the FA 524 power supply to a PC using a USB (A) -
USB (B) cable
5b.- PC
–
FA 524 programming via Ethernet. Connect the power supply and the PC via Ethernet
cable, connect these on the same LAN (the power supply provided with the address 192.168.0.222).
If it is necessary to be connected when not connected to the LAN itself, the
must be enabled beforehand.