ITRON WaterMind v2 Installation Instructions Download Page 2

2 - WaterMind Advanced Logger Overview 

3 – Inventory

WaterMind v2 Advanced Logger is provided with a fl ow cable for pulse input connection and a coiled tube per pressure 
transducer for pressure input, at no additional cost.
However, the USB cable is not included. It can be ordered as a spare part.

1

5

2

6

1

2

3
4
5

7

8

9

10

11

3

4

1

1

2

2

3

3

4

4

5

5
6
7

8
9

11

10

One-quarter Turn screw
Bidirectional Flow Input (Pulse)
Pressure Transducer
USB Connection for PC
Label

Itron Logo
Product Name
Product Code
Serial Number
Manufacturing Date
Itron Web Address
Itron Address

Country of Origin marks
Crossed out wheeled 
dust bin
QR Code
 

Product Code 

 

Serial Number 

 

Manufacturing Date

CE Marking

It is strongly recommended to install Watermind in conditions that prevent freezing, especially for models with pressure 
sensors, where water goes through the coiled tube to the product.

Ambient Operating Temperature

-10°C to +50°C

Battery Lifetime

5 years minimum (with one daily dial-up, under normal working 
conditions, depending on confi guration, temperature and location)

Dimensions

Diameter

A

mm

115

Height

B

mm

140

Total Height

C

mm

155

Fast Couples Height

D

mm

15

A

D

B

C

www.itron.com

9 rue Ampère

71031 Mâcon, France

Country of Origin: UK

WM_LOG_1P_1Pr_3G

S/N: 150156

2018/04/01

WaterMind Advanced Logger

WM_LOG_USB_CABLE

WaterMind USB Cable

(Spare part)

WM_LOG_SP_FLOW_C

WaterMind Spare Flow Cable

WM_LOG_SP_COILTUBE

WaterMind  

Spare Coiled Tube for pressure 

transducer conncetion (2.8m)

Summary of Contents for WaterMind v2

Page 1: ...M GPRS 3G communication networks for data transfer 850 900 1800 1900MHz GSM and 800 850 900 1900 2100MHz UMTS The performance of these networks depends on many parameters under the responsibility of cellular operators and in no case is Itron s responsibility However the battery lifetime is impacted by the performance of the cellular network that it is connected to The estimated battery lifetime is...

Page 2: ...t Code Serial Number Manufacturing Date CE Marking It is strongly recommended to install Watermind in conditions that prevent freezing especially for models with pressure sensors where water goes through the coiled tube to the product Ambient Operating Temperature 10 C to 50 C Battery Lifetime 5 years minimum with one daily dial up under normal working conditions depending on configuration tempera...

Page 3: ...rage periods D Press and click to Close the cover Pay attention to ensure the cover fits the body C Insert the SIM Card in the slot with the SIM symbol E Commission the WaterMind v2 Advanced logger in the system This can be done at the office before going on field Device name Meter serial number Tenant settings Pulse weight Connetion type 2 3 5 wires Cellular network params APN user and password C...

Page 4: ...5 29 39 00 Fax 33 3 85 29 38 58 F Select the right wire mapping according to the meter you are connecting to the Watermind v2 Advanced Logger WaterMind Adv Logger Cyble Sensor SharpFlow 5 wires Cyble Sensor 2 wires Other Meter 3 wires White Low Frequency Green Forward Pulse Grey High Frequency White Low Frenquency Yellow Forward Pulse Brown Ground Brown Ground Brown Ground Brown Ground Yellow Flow...

Reviews: