background image

w w w . i t r o n . c o m

 1. Scope of delivery

   - RF option board for calculators
  powered by 230V main
- Installation guide

 2. General description

 The EverBlu / RF option board is designed as interface
 between the CF- meter family and the Itron system.
Itron offers a complete Data Collecting System including hand held terminals, RF 
interfaces, reading- and route-management software as well as RF software drivers.
The option board is only applicable for calculators with 230V main power supply.
Optionally two pulse collecting registers are available for connection of two external 
water meter with pulse outputs.

 3. Safety instructions

Special care must then be taken to respect the installation procedure described in this 
document to protect your safety, ensure the proper measuring performance and comply 
with guarantee terms.
Always operate your EverBlu / RF option board for the use it has been designed for.

3.1 Signs used in this document

WARNING: this sign indicates potential electrical hazards

This sign indicates a continuous current

CAUTION: this sign indicates potential hazards

 3.2  Safety

Water networks and main power supplies may operate at high pressures and high 
voltages that may cause severe physical injuries. Only qualified professionals familiar 
with involved hazards should be permitted to open the energy integrator housing and 
install the flow meter. 

Make sure your network pipe is connected to the earth.

Always switch off main power supply prior to opening the energy integrator.

4. Technical data
4.1 Operating Temperature Conditions

4 months/year : +30°C…+55°C max. 
with : 

6 h/day max +55°C or 6 h/day min < +35°C

Average temperature for 24h : 

 

< +40°C

Rest of the year max.: 

 

 

+35°C

4.2 Storage Temperature

+5°C to +35°C

4.3 Transport Temperature

Min. –20°C (<72 hours continuous)     Max. +70°C (<72 hours continuous)

4.3 Transport Temperature

 

No direct sunlight exposition. Relative humidity < 95%.

 EverBlu / RF option board 
for CF meters with main power supply 

  Mounting and operations instructions

RF main power supply connector

Optional pulse inputs

Reviews: