w w w . i t r o n . c o m
1. Scope of delivery
- RF option board for calculators
powered by 230V main
- Installation guide
2. General description
The EverBlu / RF option board is designed as interface
between the CF- meter family and the Itron system.
Itron offers a complete Data Collecting System including hand held terminals, RF
interfaces, reading- and route-management software as well as RF software drivers.
The option board is only applicable for calculators with 230V main power supply.
Optionally two pulse collecting registers are available for connection of two external
water meter with pulse outputs.
3. Safety instructions
Special care must then be taken to respect the installation procedure described in this
document to protect your safety, ensure the proper measuring performance and comply
with guarantee terms.
Always operate your EverBlu / RF option board for the use it has been designed for.
3.1 Signs used in this document
WARNING: this sign indicates potential electrical hazards
This sign indicates a continuous current
CAUTION: this sign indicates potential hazards
3.2 Safety
Water networks and main power supplies may operate at high pressures and high
voltages that may cause severe physical injuries. Only qualified professionals familiar
with involved hazards should be permitted to open the energy integrator housing and
install the flow meter.
Make sure your network pipe is connected to the earth.
Always switch off main power supply prior to opening the energy integrator.
4. Technical data
4.1 Operating Temperature Conditions
4 months/year : +30°C…+55°C max.
with :
6 h/day max +55°C or 6 h/day min < +35°C
Average temperature for 24h :
< +40°C
Rest of the year max.:
+35°C
4.2 Storage Temperature
+5°C to +35°C
4.3 Transport Temperature
Min. –20°C (<72 hours continuous) Max. +70°C (<72 hours continuous)
4.3 Transport Temperature
No direct sunlight exposition. Relative humidity < 95%.
EverBlu / RF option board
for CF meters with main power supply
Mounting and operations instructions
RF main power supply connector
Optional pulse inputs