ITRON ACT1 Manual Download Page 5

 

 

 

 

ACT1 Meter Module 

 

 
Under Innovation, Science and Economic Development Canada regulations, this radio transmitter may only operate 
using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Innovation, Science and 
Economic Development Canada. To reduce potential radio interference to other users, the antenna type and its gain 
should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for 
successful communication. 
 

Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une 
antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le 
but de réduire les risques de brouillage radioélectrique à l'intention des autres utilisateurs, il faut choisir le 
type d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas 
l'intensité nécessaire à l'établissement d'une communication satisfaisante.

 

 

RF Exposure (FCC/ISED) 

“This equipment complies with radiation exposure limits set forth for an uncontrolled environment. This equipment 
should be installed and operated with minimum distance 20 cm between the radiator and your body. This transmitter 
must not be co-located or operating in conjunction with any other antenna or transmitter.” 

 

“Cet équipement est conforme aux limites d'exposition aux radiations dans un environnement non contrôlé. Cet équipement  
do it être installé et utilisé à distance minimum de 20 cm entre le radiateur et votre corps. Cet émetteur ne doit pas être  
co-localisées ou opérant en conjonction avec tout autre antenne ou transmetteur.” 

 

Miscellaneous  

 
 The user’s manual for any product that contains this module will contain the following text:   
 

Professional Installation  

This module is intended for professional installation by the integrator. The OEM integrator is still responsible for the 
FCC compliance requirement of the end product, which integrates this module. 
 

Modification and Repairs   

To ensure FCC compliance and system performance, this device, antenna and/or coaxial assembly shall not be changed 
or modified without the express written approval of Itron.  Any unauthorized modification will void the user’s authority 
to operate the equipment.  WARNING! This device contains no user serviceable parts. Attempts to repair this device by 
unauthorized personnel may subject the person to shock hazard if removal of protective covers is attempted.  
Unauthorized repair will void the warranty and/or maintenance contract with your company. 
 

General Description 

The Itron ACT1 is an electricity metering module which includes a 902.4 MHz to 927.6 MHz transmitter as well as WiFi.  
The module operates on AC as well as DC voltage which is supplied by a host device.  
     

Recycling Information

 

 

The product you have purchased contains circuit boards. At the end of the modules useful life, under various state 
and local laws, it may be illegal to dispose of certain components into the municipal waste system. Check with your 
local solid waste officials for details about recycling options or proper disposal. 

 

About this Manual 

This technical reference guide describes the installation of the ACT1 for the Itron OPENWAY RIVA CENTRON 
meter.  

Summary of Contents for ACT1

Page 1: ... GA 30518 USA Voice 770 831 8048 Fax 770 831 8598 Certification Exhibit FCC ID SK9ACT1 IC 864G ACT1 FCC Rule Part 15 247 IC Radio Standards Specification RSS 247 ACS Project Number 16 0130 Manufacturer Itron Inc Model ACT1 Manual ...

Page 2: ...ACT1 Meter Module ACT1 Meter Module Technical Reference Guide Effective Date July 2016 ...

Page 3: ...ACT1 Meter Module Revision History The following table describes the changes to this document for each revision of the ACT1 meter module Revision Date Description of Change A July 2016 Initial Release ...

Page 4: ...tee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and...

Page 5: ...e radiateur et votre corps Cet émetteur ne doit pas être co localisées ou opérant en conjonction avec tout autre antenne ou transmetteur Miscellaneous The user s manual for any product that contains this module will contain the following text Professional Installation This module is intended for professional installation by the integrator The OEM integrator is still responsible for the FCC complia...

Page 6: ...allation The ACT1 module will be installed in the Itron OPENWAY RIVA CENTRON electric meter Shown are the meter base with metrology board the board to board connector the ACT1 module the display and the inner and outer cover ...

Page 7: ...ACT1 Meter Module Install the display on the ACT1 module by pushing metal pins of display into module connector ...

Page 8: ...ACT1 Meter Module Insert module into upper section of inner cover and connect two wired connectors to module ...

Page 9: ...ACT1 Meter Module Connect metrology and the ACT1 module using the board to board connector ...

Page 10: ...ACT1 Meter Module Install lower inner cover ...

Page 11: ...ACT1 Meter Module Install outer cover ...

Reviews: