ACE6000 User Guide
66
P.01 P.02 and MID (page 82)
On entering this display mode, the LCD is backlit and shows the first level in the display sequence. These levels
will only be displayed if the meter has been configured accordingly.
to enter the displayed level, push the display button once (long push)
to advance to the next level, push the display button once (short push)
When the end of the display level sequence has been reached, the LCD shows
End
.
On entering a display level, the LCD shows the first parameter from its non-programmable display list. These
parameter values are dependent on the meter configuration and cannot be modified using the set mode.
To display the next parameter in the list, push the display button once (short push).
Note:
There is no auto-scroll function in these display levels.
To exit these display levels, push the display button once (very long push).
After a predefined inactivity time-out period, the meter returns automatically to the normal mode.
Reset pushbutton operation
if an EOB confirmation has not been selected, an end of billing event (EOB) event occurs
if an EOB confirmation has been selected, the meter displays any pre-configured EOB confirmation string.
To confirm the EOB event, the reset button must be pushed once (long push) while the confirmation string is
visible.
Set mode
In this mode, it is possible to modify certain pre-defined meter parameters, such as date or time.
On entering this mode, the leftmost digit of the displayed parameter will be flashing.
If the digit requires modification
1.
push the display button (short push) to increment the digit value
2.
when satisfied with the modification, push the reset button (short push) to set the value and automatically
move to the next digit
If a digit does not require modification
push the reset button (short push) to move to the next digit
Repeat the above steps for all digits.
When the last digit has been set, the whole parameter will flash:
1.
push the reset button (short push) to record the value
2.
push the display button (short push) to advance to the next parameter in the list
After a predefined inactivity time-out period, the meter returns automatically to the previous alternate mode.