2
10
Hardware Installation
Parallel
Parallel
Panel Power Select
X
JP12
JP12 is used to select the power supplied to the LCD panel.
Important:
Before powering-on the system, make sure JP12’s setting
matches the LCD panel’s specification. Selecting the incorrect
voltage will seriously damage the LCD panel.
1-2 On:
1 2 V
3-4 On:
5 V
5-6 On:
3V (default)
Jumper Settings
1
3
2
6
4
5
1
3
2
6
4
5
1
3
2
6
4
5