Itowa Mini RX User Manual Download Page 17

 MINI RECEIVER WITH FIELD BUS 

 

USER MANUAL 

 

 

 

5-1 

5. SETTING THE MASTER  

5.1 GSD OR EDS FILE 

Once  the  slave  device,  in  this  case  the  TUNNER  receiver,  has  been  configured  and  is  ready  to 

operate,  it  is  necessary  to  configure  the  device  within  the  network.  To  do  this,  a  GSD  file,  used  by 

Profibus  and  Profinet,  is  supplied  with  the  equipment  or  an  EDS  file  is  provided  for  the  other  bus 

types,  which  contain  the  parameterization  data  of  the  equipment  for  communication  within  the 

network. 

The available files are: 

  Profibus: 

 itowa_01.gsd 

  Profinet: 

 GSDML-V2.3-ITOWA-ABICPRT-20170612.xml 

  CANopen: 

 EDS_ITOWA_COP_V_1_00.eds 

  DeviceNET:   ITOWA000.eds 

  EtherNET/IP:  EDS_ITOWA_EIP_V_3_0.eds 

  Modbus-TCP:  EDS_ITOWA_EIP_V_3_0.eds 

 

These files must be imported from the configuration interface of the master bus device to identify the 

equipment and configure their properties. In this way the equipment is registered in the network and 

the master can communicate with him. 

5.2 DATA SETTING 

Once the device parameters are loaded on the control interface of the master device, the inputs and 

outputs of the master are configured according to the specifications of the frame allocation document 

that is provided with the equipment. 

When importing the GDS or EDS file into the configuration application, the device is incorporated into 

the  network  and  depending  on  the  data  to  be  used,  the  required  input  or  output  bytes  are  selected 

from the configuration parameter catalogue. 

For example to read 2 bytes in a Siemens S7 1200 PLC from an ITOWA device in a Profinet network, 

the  2-byte  block  of  input  would  be  chosen  in  the  Siemens  TIA  PORTAL  configuration  software.  As 

shown in Figure 10 

 

Summary of Contents for Mini RX

Page 1: ...USER MANUAL MINI RECEIVER WITH FIELD BUS...

Page 2: ......

Page 3: ...IS FORBIDDEN TO FULLY OR PARTIALLY REPRODUCE THIS MANUAL WITHOUT THE PRIOR WRITTEN AUTHORISATION FROM ITOWA IN THE EVENT OF INFRINGEMENT ITOWA RESERVES THE RIGHT TO TAKE THE ACTION IT DEEMS NECESSARY...

Page 4: ......

Page 5: ...3 1 3 1 INTERNAL CONNECTOR 3 1 3 2 EXTERNAL CONNECTOR 3 2 4 SETTING THE SLAVE RECEIVER 4 4 4 1 NODE ADDRESS 4 4 4 2 BAUD RATE 4 4 4 3 I O SETTING 4 5 4 4 BUS TERMINATION 4 6 5 SETTING THE MASTER 5 1 5...

Page 6: ......

Page 7: ...software based on the REMOV019a version allows managing both the configuration and the communication with the network adding new functionalities to the receiver such as the increase of available manoe...

Page 8: ......

Page 9: ...the received information to the master device of the fieldbus The absence of the module is automatically detected by the equipment which waits for its connection to start the normal operation of the e...

Page 10: ......

Page 11: ...at incorporates a female DB9 connector or an RJ45 connector on the base of the housing The External Connection section describes how to connect to the BUS In this case having a non leak proof opening...

Page 12: ...ET diagram Fig 5 DeviceNET connection 3 2 EXTERNAL CONNECTOR A female DB9 connector is available at the base of the housing to connect PROFIBUS and CANopen Or an RJ45 connector for PROFINET ETHERNET I...

Page 13: ...al 1 2 3 B Line 4 RTS 5 GND BUS isolated 6 5 V BUS output isolated 100 mA max 7 8 A Line 9 Housing Shield CANopen PINOUT CANopen DB9M connector Pin Signal 1 2 CAN_L 3 CAN_GND 4 5 CAN_SHIELD 6 CAN_GND...

Page 14: ...rs Fig 8 Possible addresses range from 00 to 99 using each selector as a digit Fig 8 BCD rotary switches In the case of Ethernet bus the address of the module would become 192 168 0 XX where XX corres...

Page 15: ...where the data is stored are page 1 0xA9 Number of digital output channels 0xAA Number of analog output channels 0xAC Number of digital input channels 0xAD Number of analog input channels 0xAE Set to...

Page 16: ...4 4 BUS TERMINATION If you need to use the device as the final line element for the PROFIBUS bus you can activate the end of line impedance by joining the 3 vertical jumpers of the expansion board Fi...

Page 17: ...ed from the configuration interface of the master bus device to identify the equipment and configure their properties In this way the equipment is registered in the network and the master can communic...

Page 18: ...ting Subsequently the programming of the PLC would be performed using the bits of this data input to perform different maneuvers The frame allocation document contains the layout of the data in bytes...

Page 19: ...nt is started and will keep the manoeuvre information updated with every change that is communicated through the radio transmitter When the radio communication is cut off the data will be initialized...

Page 20: ......

Page 21: ...the general refuses avoids possible negative consequences for the environment Furthermore it allows a proper recycling process for all the pieces This implies both energy and resources saving This sym...

Page 22: ......

Reviews: