ITOOLCO WCT1000 USER’S GUIDE
1804WTC1000UG
P a g e |
9
Precautions for the Charger
1. The LED indicator lights up amber and remains lit when the unit starts charging a battery
cartridge. The indicator turns green when charging is completed.
2. This unit is for charging battery cartridges BP-80, BP-70E, BP-70EI and BP-70MH only. Do not
use the charger for any other devices.
3. Allow battery cartridges to cool before charging. Allow at least 15 minutes between charges
when charging several cartridges in succession.
4. Charge batteries at an ambient temperature of 50º-95ºF (10º-35º C). Charging time is
approximately 50-70 minutes for the BP-80, 50 minutes for the BP-70E and BP-70EI, and 70
minutes for the BP-70MH.
5. Never short circuit the output terminals.
6. Do not expose the charger to water, oil or solvents.
7. Do not disassemble, attempt to modify, drop or otherwise abuse charger.
TROUBLE SHOOTING GUIDE
Problem
Cause
Solution
Motor runs, but tool
jaws will not advance
Insufficient hydraulic oil
Consult factory for repair service.
Air block in hydraulic system
Invert tool to allow air to rise towards the
top of the oil bladder.
Defective hydraulic circuit
Consult factory for repair service.
Motor runs, tool jaws
advance, but will not
build pressure
Insufficient hydraulic oil
Consult factory for repair service.
Defective suction valve or bypass
cartridge
Consult factory for repair service.
Insufficient hydraulic oil
Consult factory for repair service.
Motor will not
run at all
Defective battery
Charge or replace battery.
Bad contact or loose battery
connections
Check all connections and wires.
Misaligned switch
Check to make sure switch is properly
aligned with the trigger.
Consult factory for repair service.
Tool jaws will not
release
Tool did not complete a full cycle
and bypass
Press trigger and allow tool to bypass.
Then release tool jaws.
Connector is jammed in tool jaws
Press and hold release trigger while
prying tool jaws apart.
Release trigger is bent or misaligned Consult factory for repair service.