11
Original notice - T1.10
IB-P03
T
echnical
documenTaTion
5. f
acTory
reseT
Procedure
To reset IB-P03 to factory setting, refer to the procedure bellow:
1 - Ensure that the control board is properly supplied. (At least control power supply) There’s no need to
disconnect the motor rollers, sensors, or LAN cable.
2 - Remove the black rubber cover from IB-P03
3 - Use metallic tool (as a flat screwdriver) to make contact between pads for at least 3 seconds. Initialization
is complete when LEDs are flashing at the same time.
4 - Put back the black rubber cover.
Keep in mind that IB-P03 IP address will be reset to factory setting, as 192.168.1.1. User must pay attention
for any IP address conflict after IB-P03 reset.