Transmission
Window %
When you do infrared inspections through IR windows, not all of the infrared energy emitted from the target is
transmitted through the optical material in the window. If you know the transmission percentage of the window,
adjust the transmission percentage in the Imager or in SmartView software to improve the accuracy of the
measurement.
When you do not do infrared inspections through an IR window, set the Window % to 100 % to disable the
correction percentage.
RH % and Distance (m)
The distance of the Imager to the target and the relative humidity can affect the temperature reading. The farther
the Imager is from the target, the greater the humidity affects the temperature reading. Set a non-zero value for
both the
RH %
and the
Distance
.
Note
If either the RH % or the Distance value is set to zero, the applied correction of both values is disabled.
Spot Boxes
Use the Spot Boxes feature to select the number of temperature measurement zones (boxes) to center on the
target and to adjust the sizes or position of the boxes. The boxes expand or contract to different levels within the
infrared image. Each box shows an approximate maximum (MAX), average (AVG), and minimum (MIN)
temperature measurement in that area.
Note
When you use Spot Boxes, the level and span of the Imager adjusts to the thermal scene within the Spot
Boxes.
To set the size and position of a Spot Box:
1. Select
Measurement
>
Spot Boxes
.
2. Select the number of Spot Boxes.
in the new menu toggles between Size and Position.
3. If necessary, push
to select Size.
4. Push:
•
W
to decrease the vertical size of the Spot Box.
•
X
to increase the vertical size of the Spot Box.
•
Y
to decrease the horizontal size of the Spot Box.
•
Z
to increase the horizontal size of the Spot Box.