Summary of Contents for RLC-0201-GUI

Page 1: ...Toll Free 1 866 624 8309 www itl llc com Installation and Operation Manual RLC 0201 UNI GUI Universal LED Incandescent A 1Controller...

Page 2: ...ty period please contact ITL LLC in order to obtain a Return Authorization Number RMA In no event shall ITL LLC s liability exceed the price paid for the product from direct indirect special incidenta...

Page 3: ...e serious injury and or death Do not attempt to service this equipment with line power applied Do not rely on interlock switches to remove lethal voltages from the system Measure for voltages using a...

Page 4: ...ment 6 Obstruction Lights 6 Mechanical 6 Electrical 6 Installation 7 Unpacking your RLC 201 Controller 7 Quick Installation Guide 7 RLC 201 Controller Mounting 8 Electrical Connections 9 Connector Des...

Page 5: ...stall test and troubleshoot the RLC 201 Product Description Both the RLC 0201 UNI and RLC 0201 GUI are capable of controlling one FAA type L 864 L red LED or FAA type L 864 incandescent beacon and up...

Page 6: ...1700 or One Dialight D564 Series LED Beacon or One Dialight D464 Series LED Beacon or One Dialight D264 Series LED Beacon Side Lights Up to Five Incandescent 116W or 100W 120 or 230 Vac Up to Five LE...

Page 7: ...nstall the RLC 201 controller Remove RLC 201 controller from packaging material Mount the RLC 201 enclosure Install FAA type L 864 Incandescent Beacon or FAA type L 864 L LED Beacon per manufacturer s...

Page 8: ...RLC 201 DOC RLC201 MNL Rev10 doc 12 18 2020 Copyright 1999 2020 ITL LLC Page 8 of 15 RLC 201 Controller Mounting...

Page 9: ...P2 P3 and P4 located at the bottom of the controller Connections for alarm relays are made on P5 and P6 located on the right side of the controller Typical connections for a 120VAC system are shown be...

Page 10: ...or Terminals Function P1 L1 N Input Power Line Voltage Input Power Neutral P2 PRI N SEC Primary Beacon Power Supply Neutral Secondary Beacon P3 MKR N Marker Light Power L 810 obstruction light power M...

Page 11: ...p and operation of the RLC 201 is performed using the Configuration Jumpers Configuration DIP Switches the Marker Alarm Setting dial and the Manual Mode Select Switch Configuration Jumpers Manual Mode...

Page 12: ...N Marker alarm is disabled OFF Marker alarms is enabled 4 Beacon Type 1 ON ITL IFH 1900 or Dialight D464 or D564 5 Beacon Type 2 ON ITL IFH 1700 or Dialight D264 6 Marker Type See Marker Configuration...

Page 13: ...ell Indicator Lights Indicator Lights Description Function DAY MODE Steady Day mode operation via photoelectric cell Flashing Day mode operation via manual mode select switch NITE MODE Steady Night mo...

Page 14: ...Beacon LED MKR S750 0DH L 810 Obstruction Light Incandescent MKR LTG1 0IR L 810 L Obstruction Light LED with Infrared MKR LTE1 000 L 810 L Obstruction Light LED MKR LTE1 0IR L 810 L Obstruction Light...

Page 15: ...ate Preparer Approval 10 Updated board layout pg 9 pg11 Updated Jumper configuration added IFH 1900 LTG Updated Spare Parts Replacement Parts List 12 18 2020 Prepared By Elke Hinson Approved By Josh C...

Reviews: