Figure 1. WIS Battery Cover Removal and DIP
Switch Locations
DIP Switch 1—Battery Type
ν
OFF—Install an alkaline or lithium type battery.
ν
ON—Activates a trickle charge circuit for use
with a NiCd battery.
WARNING:
Never turn on DIP switch 1 when using an
alkaline or lithium battery. Personal injury
and equipment damage may result if these
batteries are recharged, short-circuited,
punctured, or discharged at higher than
acceptable rates.
DIP Switch 2—External Siren Delay
ν
OFF—External siren terminals activate immedi-
ately during an alarm condition.
Use this setting when the siren connected to the
external siren terminals is located inside the pre-
mises.
ν
ON—External siren terminals activate 15 seconds
after an alarm condition occurs.
Use this setting when the siren connected to the
external siren terminals is located outside. This
helps prevent disturbing neighbors in cases of
accidental alarms that last less than 15 seconds.
DIP Switches 3 and 4—Status Tones
ν
3 and 4 OFF—The WIS internal piezos and exter-
nal siren do not produce any status tones.
Use this setting when the WIS is installed in or
near sleeping areas.
ν
3 ON, 4 OFF—The WIS internal piezos produce
normal-volume status tones.
Use this setting when the WIS is installed in areas
where status tones need to be heard.
ν
3 OFF, 4 ON—The WIS internal piezos and exter-
nal siren produce high-volume status tones.
Use this setting when status tones need to be
heard in remote areas, inside and outside of the
premises.
CAUTION:
Never turn on both DIP switches 3 and 4
together; otherwise, permanent damage
may occur to the WIS.
Wiring
Figure 2 shows how to connect the Hardwire Exterior
Siren (13-046) to the WIS external siren screw termi-
nals.
CAUTION:
Only the Hardwire Exterior Siren can be
connected to the WIS terminals. Other
sirens may draw more current than the
WIS can provide and cause permanent
damage to the WIS.
Figure 2. Connecting the Hardwire Exterior Siren
to the WIS
Programming
This section describes how to program and change a
house code in the WIS so that it can respond to panel
signals.
1052G73A.DS4
DIP SWITCHES
HARDWIRE EXTERIOR SIREN (13-046)
100 mA MAXIMUM DRAW
1052G74A.DS4
RED
BLACK