Page 1
Audio Verification Module
n
Use a maximum of 500 feet of cable for all
speakers and microphones.
Tools Needed
n
Phillips screwdriver
n
Mounting screws and anchors (included)
n
Drill and bits
n
3-conductor, 22-gauge shielded stranded wire
n
2-conductor, 18-gauge stranded wire
Installation
To mount the AVM:
1.
Route both 2 and 3-conductor wire cables from
the module to the panel.
2.
Remove the cover screws from the module cover
and rotate it away from the base. Set the cover
and screws aside.
3.
Remove the speaker plate screws and lift the
speaker plate off the back box (see Figure 1).
Figure 1. Removing the Speaker Plate
8557113A.DS4
SPEAKER
PLATE
Interrogator
®
200 Audio
Verification Module (AVM)
Document Number: 466-1621 Rev. A
October 1998
Installation
Instructions
Product Summary
The Interrogator 200 Audio Verification Module
(AVM) gives the central station operator the ability to
hear what’s happening at the premises during an
alarm and speak directly to the system owner. The
operator can determine how serious an alarm is, find
out what kind of help is needed, and dispatch the
appropriate assistance.
Control Panel Compatibility:
SIMON ™
Only Version 2 (# 60-776)
Installation Guidelines
Use the following guidelines when installing the
AVM:
n
You can install one AVM per panel.
n
Wire speakers (voice terminals) in series and the
DC voltage, ground, and microphone wires in
parallel.
n
Use separate cables for the speakers and the
power, ground, and microphone wires to prevent
cross talk between the microphone and the
speaker.
n
Use 3-conductor, 22-gauge shielded wire from the
AVM power, ground and microphone to the
panel. Shielded cable reduces electrical noise and
cross talk.
n
Use 2-conductor, 18-gauge wire from the speakers
to the panel.
60-787
8569G04A.DS4