SuperBus® 2000 4-Relay Output Module

Programming and Testing

2.

Connect the panel battery(s) and restore panel AC 
power. Alphanumeric touchpad displays should come 
on. Both the green and red LEDs turn on for one sec-
ond, then the green POWER LED will remain on.

3.

Press 8 for System Menu.

4.

Press 0 for Program Menu.

5.

Enter your Install Code (default 0123).

6.

Enter Item Number 48001 to add SuperBus 2000 
devices. All installed devices are automatically added 
(learned) into panel memory when Devices Added is 
indicated.

7.

Press * twice to return to the Main Menu.

8.

The red BUS status LED should flash to indicate suc-
cessful communication with the panel.

Note

If the green POWER LED is not on or the red BUS 
status LED does not flash, remove AC panel power, 
disconnect the battery(s), and see Table 6 “Trouble-
shooting.”

UltraGard Panels

1.

Verify that all wiring at the panel and the module is 
correct.

2.

Verify nonconflicting bus unit number settings. 

3.

Connect the panel battery and restore panel AC power.

4.

Turn on the panel AC power.

5.

Set the

 

UltraGard

 

panel RUN/PROGRAM switch to 

PROGRAM.

If the alphanumeric touchpad displays 1-OFF and the 1 is 
flashing, you must enter the 4-digit installer access code to 
get the panel into program mode.

Alphanumeric touchpads should display PROGRAM 
MODE
 and the red BUS status LED on the module should 
be flashing continuously, indicating successful communica-
tion to the panel.

Note

If the green POWER LED is not on or the red BUS 
status LED does not flash, set the RUN/PROGRAM 
switch (UltraGard) to RUN, remove AC panel power, 
disconnect the backup battery, and see Table 6 “Trou-
bleshooting.”

Programming and Testing

Refer to the specific panel Installation Instructions for 
configuring module outputs, adding (learning) hardwire 
sensors, and testing.

Troubleshooting

Use the following table to determine possible solutions to 
module problems.

Table 6: Troubleshooting

Problem

Solution

The green POWER 
LED stays off.

1.

Check for incorrect wiring con-
nections.

2.

Make sure panel AC power is 
applied and the backup battery(s) 
are connected.

3.

If the LED still remains off, 
replace the module.

The red BUS LED 
doesn’t flash to 
indicate 
communication 
with the panel.

1.

Verify that the panel recognizes 
the module by entering program 
mode (see specific panel Installa-
tion Instructions
).

2.

Check for incorrect wiring con-
nections.

3.

For Concord (software versions 
1.0–1.6) and UltraGard panels 
make sure that module DIP switch 
1 is set to “M.” For Concord (soft-
ware versions 2.0 or later) and 
Advent panels make sure that 
module DIP switch 1 is set to “A.”

4.

If the LED still doesn’t flash, 
replace the module.

Output(s) activate 
only momentarily, 
activate randomly, 
or module and/or 
touchpads lock up.

1.

For Concord (software versions 
1.0–1.6) and UltraGard systems, 
check for bus devices with the 
same unit number setting.

2.

Re-initialize the panel by discon-
necting and reconnecting panel 
power.

3.

Verify that the output/point is con-
figured correctly (see specific 
panel Installation Instructions).

4.

Make sure the zone has been 
“learned” into panel memory.

5.

Verify that the panel recognizes 
the module by entering program 
mode (see specific panel Installa-
tion Instructions
).

6.

Check module/panel wire routing 
and length.

7.

Replace the module.

Module Zone input 
is inoperable.
(UltraGard & 
Concord)

1.

Some panels and panel versions 
do not read the module built-in 
zone input status. Use a panel zone 
input instead.

One output stays 
activated.

1.

Check if the point is programmed 
for a 3 minute “on” time and if the 
triggering event for the point is 
repeatedly “resetting” the 3 
minute timer (see specific panel 
Installation Instructions).

2.

Output may have failed or been 
overloaded. Reprogram using a 
different (unused) module output 
or replace the module.

Summary of Contents for 60-770 - Security SuperBus 2000 4-Zone Output Module

Page 1: ...ates manually setting DIP switches and the chance of identical unit number conflicts SuperBus 2000 Panels Advent Concord software versions 2 0 and later SuperBus panels communicate with SuperBus 2000...

Page 2: ...th Concord cabinet Installation The relay output module can be mounted On a wall Inside an Advent cabinet Inside a Concord cabinet Inside a SuperBus Module cabinet 60 698 Refer to the cabinet Installa...

Page 3: ...the module back plate onto the two clips located on the top left corner or center of the cabinet Figure 6 Note The two mounting clips in the top right corner of the cabinet are designated for a receiv...

Page 4: ...e the module to the panel as shown in Figure 7 and Table 4 Note For specific wiring details see the panel Installation Instructions 3 Wire multiple modules in daisy chain fashion in parallel to the pa...

Page 5: ...the switch to the module zone input terminals or unused panel hardwire input termi nals Once programmed if someone opens the module cover the tamper switch opens and causes an alarm The tamper switch...

Page 6: ...ches for the desired unit number Figure 11 Unit Number 0 7 for UltraGard Unit Number 0 7 for Concord software versions 1 0 1 6 Figure 11 Module Unit Number DIP Switch Settings Non SuperBus 2000 system...

Page 7: ...sting Troubleshooting Use the following table to determine possible solutions to module problems Table 6 Troubleshooting Problem Solution The green POWER LED stays off 1 Check for incorrect wiring con...