ITI 135310 Operation Manual Download Page 4

V

ISUAL 

E

YEPIECE

 

 

The Visual Eyepiece screws onto the “C” mount.  The “C” Mount Extender should not be used when the Eyepiece 
is in place - you will not be able to obtain proper focus. 
 

F

OCUSING

 

 
Start with the RVI out of focus.  Rotate Focus Ring so that focus is achieved and continue past clear focus.  
Rotate Focus Ring in opposite direction to re-establish clear focus.  
 

R

IGHT 

A

NGLE 

A

DAPTER

 

 
Slide Right Angle Adapter onto the blade, with mirror facing up, until it clicks in place.  Note that the image 
reverts, left/right, when using this adapter.  Use caution when removing Right Angle Adapter from blade.  Grasp 
Right Angle Adapter by its sides and gently pull away from RVI. 
 

CAUTION

  

 

THE MIRROR SURFACE ON THE RIGHT ANGLE ADAPTER SHOULD 

NEVER BE TOUCHED

.  TOUCHING 

THE MIRROR WILL CAUSE SCRATCHES OR A DIRT BUILD-UP THAT WILL DETERIORATE THE IMAGE 

QUALITY. SEE CLEANING INSTRUCTIONS. 

 
 

 

Summary of Contents for 135310

Page 1: ...estfield MA 01086 33 Airport Road Westfield MA 01085 Tel 413 562 3606 Fax 413 568 9809 Email iti scopes com www scopes com INSTRUMENT TECHNOLOGY INC OPERATION MANUAL MODEL 135310 UNDER DOOR REMOTE VIE...

Page 2: ...ear after the date of shipment when used in accordance with the directions for use and agrees to repair or replace any such defective component part at no cost to the customer There are no other expre...

Page 3: ...e carefully inserted under a doorway Never use the RVI to pry door If there is insufficient space to insert blade of scope use a Uni Bar to gently lift door then insert blade The Uni Bar is an availab...

Page 4: ...to re establish clear focus RIGHT ANGLE ADAPTER Slide Right Angle Adapter onto the blade with mirror facing up until it clicks in place Note that the image reverts left right when using this adapter U...

Page 5: ...ch ITI Model 126070 41mm Visual Adapter to the back of the Eyepiece 3 Remove lens from ITI Model 135630 NVPS Screw NVPS onto the back of the Visual Adapter Remove protective cap from NVPS and attach r...

Page 6: ...the NVPS relay lens to the ITI Model 135630 NVPS lens will only adapt one way 4 If using a 1 2 format CCD camera just simply screw on the camera For use with 1 3 CCD cameras use the C Mount Extender s...

Page 7: ...tter Plate by black plastic housing flat side down Slide distal end of plate underneath door 2 Slide or pivot Infrared Emitter Plate around to vary intensity of Infrared light emitted into room 3 To d...

Page 8: ...age Not Clear Dirt on external optical surfaces Clean optics Scope not focused Focus scope Dirt or liquid on internal optical surfaces Return to ITI for repair 1 3 CCD without C Mount Extender Use C M...

Page 9: ...exposed wiring It is an excellent conductor REPAIR POLICY If your equipment requires factory attention contact ITI s Customer Service Dept at 413 562 3606 for a Return Authorization Number Please be...

Reviews: