12
OFF
ON
Warning!
If the fan is internally contaminated, it must be cleaned by a
recognised installer. The user/consumer must not unscrew
the device. However, the decorative cap (magnetic lock) can
be removed to wipe the surfaces with a slightly damp cloth.
4.
Set up
4.1.
Setting the Timer
4.2.
Setting the Hygrostat
The timer (delay time) can be set. On delivery, the shut-off delay
is set to approximately 10 minutes. If required, this time can be
altered by turning the adjusting potentiometer (behind the
curved trim panel) from 3 minutes (anti-clockwise) to 25 minutes
(clockwise). The time must be determined by experiment.
Switching on by the humidity switch takes place automatically if
the humidity level in the room exceeds the set value. The
switching point (relative humidity) can be set between 40%
(counterclockwise) and 95% (clockwise) by means of the setting
potentiometer. The adjusting potentiometer is located behind the
decorative plate.
5.
Service & Maintenance
The fan requires little maintenance. Wiping with a slightly
damp cloth is usually sufficient.
TIMER
3
25
-
TIMER
3
25
-
HY%
40
95
-