Technical data
Page 40
4.3
Supply [X9]
Table 10:
Technical data: Performance data [X9]
Type
Supply voltage
1 x 100 ... 230 VAC [± 10 %], 50 ... 60 Hz
In continuous operation maximum of mains
current
2,4 A
RMS
4,7 A
RMS
10 A
RMS
Intermediate circuit voltage (at an operating
voltage of 230 VAC)
310 ... 320 VDC (without PFC)
360 ... 380 VDC (with active PFC)
310 ... 320 VDC
Alternative DC supply
60 ... 380 VDC
60 ... 320 VDC
24 V supply
24 VDC [± 20 %]
(0,55 A)
*)
24 VDC [± 20 %]
(0,65 A)
*)
*)
plus current consumption of a possibly connected holding brake and I/Os
Table 11:
Technical data: Internal brake resistor [X9]
Type
Brake resistance
60
Ω
60
Ω
37
Ω
Pulse power
2,8 kW
2,8 kW
3,9 kW
Continuous power
10 W
20 W
25 W
Threshold limit
(without PFC)
(with active PFC)
389 V
440 V
389 V
440 V
389 V
(no PFC)
Over-current detection (without PFC)
(with active PFC)
400 V
460 V
400 V
460 V
400 V
(no PFC)
Table 12:
Technical data: External brake resistor [X9]
Type
Break resistance
≥
50
Ω
≥
50
Ω
≥
25
Ω
Continuous power
≤
2500 W
Operating voltage
≥
460 V
≥
460 V
≥
400 V