ITEC DIGIPOWER 2x500T - INTRODUCTION

Dear Customer, 

The power amplifi ers of the series “ITEC DigiPower”  offer due to the latest digital technology in place an 
extremely high effi ciency. Another feature is the very low power consumption in the automatic standby mode. 
Therefore “ ITEC DigiPower amplifi ers” are ideal for the use in voice alarm systems. For this application 
alternatively to the standard 230V AC power supply a supply from a 24V DC backup battery can be 
provided.

LEDs on the front panel show the proper function of the power amplifi er and the power supplies. 
This information can be passed on to higher-order control and fault indication systems via fl oating  relay 
contacts. 

ITEC DigiPower amplifi ers are very robust and reliable. They are designed for a continuous operation in pro-
fessional sound reinforcement systems. Dynamic limiters provide an effective overload protection and avoid 
distortion or damages of the speaker systems. Short-circuit and over temperature protection ensure a maxi-
mum operational safety. Various practical details and the convenient, streamlined design facilitate installation 
and operation.

Please read this instruction manual carefully and observe all instructions in particular those safeties related 
to ensure a long lasting and trouble-free operation.

We are happy to assist you in any other questions concerning sound, voice alarm, security, sound, speech 
technology, media remote control, conference room facilities, etc.

Your ITEC acoustics team

ITEC DigiPower 2x500T – Features

• 

LED indicators for signal and operating conditions

• 

Monitoring contacts for battery

• 

Monitoring contacts for the output amplifi er

• 

2 channels in a 19-inch, 2 units of height case

• 

Low installation depth of only 260 mm

• 

All feed lines with plug-in, screw terminals

• Balanced 

Inputs

• 

Automatic standby mode

• 

Protection against open circuit, short circuit, over temperature, DC

• 

230V AC and 24V DC power supply

• 

Switching on delay

Summary of Contents for DIGIPOWER 2x500T

Page 1: ...DIGIPOWER 2x500T POWER AMPLIFIER MANUAL VERSION 1 0 MARCH 2019 Designed and Manufactured by ITEC Tontechnik und Industrieelektronik GesmbH 8200 Laßnitzthal 300 Austria Europe DI IG GI IP PO OWER 2x500T ...

Page 2: ... provide an effective overload protection and avoid distortion or damages of the speaker systems Short circuit and over temperature protection ensure a maxi mum operational safety Various practical details and the convenient streamlined design facilitate installation and operation Please read this instruction manual carefully and observe all instructions in particular those safeties related to ens...

Page 3: ... feeder Before connecting to the mains supply check that the data on the backside of the device match with the local network The device must necessarily be checked by trained personnel in case The power cable or plug are damaged small objects or liquids got into the device the device operates in a different way than usual the device was exposed to a severe impact or the housing has been damaged Ex...

Page 4: ...t in limiter to prevent a clipping of the signal 4 Channel 2 Fault as item 2 but for channel 2 5 Channel 2 Clip as item 3 but for channel 2 6 230V AC indicates that the applied voltage is 230V AC The device is supplied by this voltage the 24V DC remains unloaded 7 Channel 1 Operating Mode Indicates that channel 1 is active This means a signal at input 1 is present which is amplified If no signal i...

Page 5: ...DIGIPOWER 2x500T BLOCK DIAGRAM ITEC DigiPower 2x500T Block diagram 230 V AC 24 V DC 230 V OK 24 V 24 V OK CH 1 OK 100 V 50 V 0 IN 1 1 4 1 5 1 6 2 4 2 5 2 6 1 7 2 7 1 8 2 8 Protect 24 V Volume 1 1 CH 2 OK 100 V 50 V 0 IN 2 Protect 24 V Volume 2 2 ...

Page 6: ...a minimum level 40mA for measurements 13 CH 1 Volume Volume control for channel 1 adjustable with a little screwdriver 14 1 IN1 Balanced signal input for channel 1 15 1 IN2 Second symmetrical signal input for channel 1 If the corresponding terminal is Switch IN2 to set to GND this signal is alternatively used instead of 1 IN1 16 SWITCH IN2 Used for switching from 1 IN1 to 1 IN2 Becomes active when...

Page 7: ...V OK 230V OK 230V OK 13 14 20 15 16 17 18 19 21 22 23 24 25 26 20 CH 2 Volume like item 13 but for channel 2 21 2 IN1 like item 14 but for channel 2 22 2 IN2 like item 15 but for channel 2 23 SWITCH IN2 like item 16 but for channel 2 24 PILOTTONE like item 17 but for channel 2 25 CH 2 OK like item 18 but for channel 2 26 230V OK Floating contact closed when the 230V AC power is applied properly 27...

Page 8: ...emperature Dimensions 482 x 88 x 260 mm W x H x D 19 2HE Weight 16 5 kg ITEC DIGIPOWER 2x500T SPECIFICATIONS 482 mm 88 mm Depth 260 mm No responsibility is taken for the correctness of this information Specifications subject to change 431 mm ITEC Tontechnik und Industrieelektronik GesmbH A 8200 Lassnitzthal 300 Austria Europe Tel 43 0 3133 3780 0 office itec audio com www itec audio com USE ONLY F...