Disassembly/Assembly
Disassembly
Tools Required
You will need a #2 Phillips screwdriver.
Workspace Recommendations
A countertop or flat surface is ideal for disassembling/assembling your unit. You
will need 2 ft. x 3ft. of clean, accessible workspace. It is recommended to use a small
bowl or cup to hold any screws so they are not lost during the disassembly process.
Disassembly Instructions
1. Turn the unit off.
2. Remove the Power Cord from the wall and rear of the unit.
3. Clean exterior of unit if necessary (see “
CLEANING: Unit Exterior
” page 17).
Removing the Rear Cover:
1. Using your screw driver, remove the
Rear Cover Screw
from the
Rear Cover
(above the
Power Cord Port
). Place the
Rear Cover Screw
where you will
find it easily during reassembly.
2. Squeeze the tabs on both sides of the
Rear Cover
(where the grooves are) until
they release and tilt the
Rear Cover
upwards until the top tab releases. Clean
with compressed air or a damp cloth. Set the
Rear Cover
aside.
Removing the Filter Assembly:
1. Remove
Brass Thumbscrews
from the top corners of the
Filter Assembly
.
Place
Brass Thumbscrews
where you will find them easily during reassembly.
2. Grasp the top of the
Filter Assembly
and tilt away from the unit. Clean if
necessary (see “
CLEANING: Filter Assembly
” page 17) and set the
Filter
Assembly
aside.
3. Lift tabs on either side of
Filter Assembly
to remove the rim and access the
separate honeycomb, foam and mesh layers.
Removing the Purification Plate:
Grasp the
Purification Plate
on the ceramic and gently pull it out of the grooves on
the sides. Clean (see “
CLEANING: Purification Plate
” page 17) and set the
Purification
Plate
aside.
Removing the PCO Cell:
1. Locate the
PCO Cell Power Connector
on the right of the rear of the unit
almost halfway up the unit (beside the
Purification Plate
slot). Squeeze the
tabs on the top and bottom of the
PCO Cell Power Connector
and pull gently
until free from the
PCO Cell Power Connector Outlet.
2. Remove the
Thumb Nuts
from the
Screw Posts
on the right and left below the
PCO Cell
. Place the
Thumb Nuts
where you will find them easily during
reassembly.
3. Gently slide the
PCO Cell
out of the unit. Clean (see “
CLEANING: PCO Cell
”
page 17) and set the
PCO Cell
aside.
Clean the interior of the unit (see “
CLEANING: Unit Interior
” page 17).
Removing the Front Grille:
1. Locate the four
Front Grille Screws
in the four corners of the
Front Grille
.
Using your screw driver, carefully remove the four
Front Grille Screws
.
Place
the
Front Grille Screws
where you will find them easily during reassembly.
2. Remove the
Front Grille
carefully to ensure that the
Ionization Needle
(in the top
center of the front of the unit) is not damaged. Clean the
Front Grille
if necessary
(using compressed air, vacuum cleaner, damp cloth or warm soapy water)
and set the
Front Grille
aside.
3. Clean the
Ionization Needle
if necessary (see “
CLEANING: Ionization Needle
”).