background image

An all-pole mains switch with a contact separation of at least 3 mm in each pole shall be incorporated in
the electrical installation of the building.

When Installing the Unit

    Never  plug  in  nor remove the power  supply  plug
    with  wet  hands,  as  doing  so  may cause electric
    shock.

    When unplugging  the  power  supply cord, be sure
    to grasp the  power  supply  plug; never  pull on the
    cord  itself.  Operating   the  unit   with  a  damaged
    power  supply  cord  may  cause  a  fire  or  electric 
    shock.

    When moving the unit, be sure to remove its power 
    supply cord  from the  wall  outlet.  Moving  the unit
    with the  power  cord  connected  to  the outlet may
    cause damage to the power cord, resulting in fire or 
    electric shock. When  removing the power cord,  be
    sure to hold its plug to pull.

  Do not block the ventilation slots in the unit's cover.
  Doing so may cause heat to build up inside the unit 
  and result in fire.

  Avoid installing the unit in humid or dusty locations,
  in locations exposed to the direct sunlight, near the 
  heaters, or in locations generating  sooty smoke or
  steam  as  doing  otherwise  may  result  in  fire  or 
  electric shock.

When the Unit is in Use

    Do not place heavy objects on the unit as  this  may
    cause   it  to  fall  or  break   which   may   result   in 
    personal   injury    and/or    property    damage.   In
    addition,  the  object  itself  may  fall  off  and  cause
    injury  and/or  damage.

    Make  sure   that   the  volume   control   is   set   to
    minimum  position   before  power  is  switched   on.
    Loud noise produced at high volume when power is 
    switched  on  can  impair  hearing.

    Do not operate  the  unit  for an  extended  period of 
    time with  the sound distorting. This  is  an indication
    of  a  malfunction,  which  in  turn  can cause heat to
    generate and result in a fire.

    Contact your 

 dealer as  to the  cleaning. If  dust

    is  allowed  to accumulate  in  the  unit  over  a  long 
    period of  time, a  fire  or  damage  to  the  unit  may 
    result.

ITC

  If dust accumulates on the power supply plug or in
  the  wall  AC  outlet,  a  fire  may  result.  Clean  it 
  periodically. In addition, insert the plug in the wall 
  outlet securely.

  Switch off  the  power, and unplug the power  supply
  plug  from the  AC outlet  for  safety  purposes when 
  cleaning  or  leaving the unit unused for  10  days or 
  more. Doing otherwise  may cause a fire  or  electric 
  shock.

SAFETY PRECAUTIONS

4

Due to product upgrades, while some of the features and specification in the user manual does not 
match the actual functions, sorry for any inconvenience and  thanks for your kind understanding!

Summary of Contents for TI-120Z

Page 1: ...PUBLIC ADDRESS SYSTEM TI 120Z 240Z 350Z 500Z HIGH EFFICIENCY MIXER AMPLIFIER USB SD SD MEDIA MODE MIC1 INPUT MIC 4 AUX 1 AUX 2 MIC 3 MIC 1 MIC 2 MASTER TREBLE BASS 10 0 10 0 10 0 10 0 10 0 10 0 PROT S...

Page 2: ...ERAL DESCRIPTION 5 3 FEATURES 5 4 NOMENCLATURE AND FUNCTIONS 4 1 Front Panel 6 4 2 emote control 6 4 3 Rear Panel 7 5 OPERATION ILLUSTRATION 8 6 11 7 APPLICATIONS 12 8 BLOCK DIAGRAM 13 9 SPECIFICATION...

Page 3: ...in fire or electric shock Be sure to replace the unit s terminal cover after connection completion Because high voltage is applied to the speaker terminals never touch these terminals to avoid electr...

Page 4: ...in Use Do not place heavy objects on the unit as this may cause it to fall or break which may result in personal injury and or property damage In addition the object itself may fall off and cause inju...

Page 5: ...e input microphone has priority over line input MIC1 takes precedence over other audio input EMC takes precedence over all audio inputs 6 Channel priority function EMC MIC1 MIC2 MIC3 MIC4 AUX1 AUX2 MP...

Page 6: ...mote control MODE EQ STOP 1 2 3 4 5 6 7 8 9 10 8 USB SD SD MEDIA MODE MIC1 INPUT MIC 4 AUX 1 AUX 2 MIC 3 MIC 1 MIC 2 MASTER TREBLE BASS 10 0 10 0 10 0 10 0 10 0 10 0 PROT SIG CLIP CH1 CH2 CH6 CH5 CH3...

Page 7: ...output ports 3 Cooling fan 4 EMC input port 5 Line output interface is used to connect the line input interface of other equipment 6 Two line input interfaces are used to connect the line output inter...

Page 8: ...n off the equipment and then turn off the connected equipment 1 Connect the speakers 1 Before connecting the speakers please make sure that the equipment is powered off In the case of power on may hav...

Page 9: ...using the built in MP3 player buttons please pay attention the strength when control avoid excessive force to cause damage of MP3 player button 2 When insert SD card or USB interface Please insert in...

Page 10: ...n will be automatically connected and after the pairing is completed the mobile music will be played normally 8 FM module radio function description First connect the antenna that is packaged with the...

Page 11: ...3 The volume knob is not opened or turned down to a extra low level 4 There is no audio signal input 5 There is short circuit in the speaker line 3 The sound suddenly disappears in normal status 1 The...

Page 12: ...1 OUTPUT INPUT COM ZONE OUTPUT Z1 COM Z2 COM Z3 COM Z4 COM Z5 COM 4 16 COM Z6 OUTPUT 70V 100V EMC G Zone6 Zone5 Zone1 4 16 T 6221 CD PLAYER T 1S240 70V 100V MIC 2 MIC 3 MIC 4 VOL PLAY MSG MIC in PLAY...

Page 13: ...udio transformer Sound control 6 zone output Master output EMC Forced switch Input Output Volume control Amplifier Master volume control Acquisition control Input Output Amplifier Input Output Amplifi...

Page 14: ...MIC 65dB Music 70dB THD N 0 1 Power Indicator Short circuit no voltage Air cooled Over temperature short circuit 5 40 20 70 95 No condensation SNR THD Indicator light Short circuit mode Cooling metho...

Page 15: ...4 5 CH4 OFF 1 2 3 4 5 OFF 1 2 3 4 5 OFF 1 2 3 4 5 OFF 1 2 3 4 5 OFF 1 2 3 4 5 USB SD SD MEDIA MODE MIC1 INPUT MIC 4 AUX 1 AUX 2 MIC 3 MIC 1 MIC 2 MASTER TREBLE BASS 10 0 10 0 10 0 10 0 10 0 10 0 PROT...

Page 16: ...PUBLIC ADDRESS SYSTEM VersionV0 1...