5. DISPLAY SCREEN OPERATION INSTRUCTIONS

Note:

1

.

Turn

 

off

 

the

 

power

 

switch,Please

 

wait

 

about

 

5

 

seconds

 

before

 

turning

 

on

 

again.Continuous

 

rapid

 

     turning

 

on

 

and

 

off

 

the

 

power

 

switch

,

it

 

will

 

lead

 

to

 

equipment

 

failure

.

2

.

Even

 

the

 

switch

 

is

 

in

 

the

 

off

 

status

there

 

will

 

be

 

a

 

little

 

current

 

in

 

equipment

If

 

it

 

won’t

 

use

 

the

 

     equipment

 

in

 

a

 

long

 

time

please

 

unplug

 

the

 

power

 

cord

 

from

 

the

 

wall

 

AC

 

socket

.

4.

1.Turning the volume knob to the left,Connect the microphone and microphone input interface.

2.Turning the volume knob in the right position.

3.Facing the microphone and Speak loudly, turn the volume knob to the right, until the output signal 

    no longer distortion.If input is high but output is low voice, and then increase the volume by using 

    the volume knob.If the speaker volume is very high, then reduce the volume by using the volume 

    knob.

Microphone using:

5.Shutdown the system:

1

.

Turning the volume knob to the left until the minimum position.

2

.

Turning off the panel power switch of the professional power amplifier, at 0ff.In turn shutoff 

    processor equipment and audio source equipment.

6. TROUBLESHOOTING

Failure phenomena 

Failure cause

1. Power switch is not opened

1 Power line is cut off
2. The protection function of the equipment is 
    not activated 

2. All lines are connected, but there is 
    no sound.

1. The power switch is not opened or the power 
    plug is bad contacted.
2. The fuse is burnt
3. The volume knob is not opened or turned down 
    to a extra low level
4. There is no audio signal input
5. There is short-circuit in the speaker line.

3. The sound suddenly disappears in 
    normal status.

1. The equipment is in very high temperature to 
     make it into protection status.
2. The connection wire is bad contact.

4. Low sound

The equipment is set to be low impedance 
connection, but the speakers connected is 
with high impedance.

5. Sound is distorted

The input level of Mic or external equipment 
is too high

Summary of Contents for T-B120D

Page 1: ...in this manual to obtain the optimum results from this unit We also recommend that you keep this manual handy for future reference PUBLIC ADDRESS SYSTEM ON OFF POWER MIC1 INPUT T B60D PROT AUX 2 MIC...

Page 2: ...ONS 3 2 GENERAL DESCRIPTION 5 3 FEATURES 5 4 NOMENCLATURE AND FUNCTIONS 4 1 Front Panel 6 4 2 Rear Panel 7 5 OPERATION ILLUSTRATION 8 6 9 7 APPLICATIONS 10 8 BLOCK DIAGRAM 11 9 SPECIFICATIONS 12 10 DI...

Page 3: ...in fire or electric shock Be sure to replace the unit s terminal cover after connection completion Because high voltage is applied to the speaker terminals never touch these terminals to avoid electr...

Page 4: ...in Use Do not place heavy objects on the unit as this may cause it to fall or break which may result in personal injury and or property damage In addition the object itself may fall off and cause inju...

Page 5: ...quipment is equipped with level indication overload and protection indicator and has good protection for short circuit overload and overheat situation 5 With mute function microphone input microphone...

Page 6: ...EL 11 12 1 2 3 4 5 6 7 8 9 10 1 MIC1 unbalanced input jack 2 MIC1 volume control knob 3 MIC2 volume control knob 4 MIC3 volume control knob 5 MIC4 AUX1 volume control knob 6 AUX2 volume control knob 7...

Page 7: ...nnect the line input interface 6 2 channel AUX input interface used to connect AUX output interface 7 Line input Mic input Phantom power switch for MIC4 8 MIC4 AUX1 Balance input 9 Line input Mic inpu...

Page 8: ...less than rated power of equipment 2 Connect external devices Please ensure that the equipment and all equipment will be connected are powered off Using the corresponding cable to connect this equipme...

Page 9: ...hone using 5 Shutdown the system 1 Turning the volume knob to the left until the minimum position 2 Turning off the panel power switch of the professional power amplifier at 0ff In turn shutoff proces...

Page 10: ...2 EMC IN MUTE G G G G MIC 1 NC G OUTPUT 100V 4 16 NC NC 7 APPLICATIONS REAR PANEL CONNECTIONS 10 OPEN CLOSE PLAY STOP NEXT PREVIOUS ON OFF POWER Audio source equipment like CD MP3 player M I C VOL PL...

Page 11: ...SS TREBLE LEVEL Protection circuit LED display Fun control Amplifier output LEVEL LEVEL LEVEL LEVEL LEVEL MUTE_MIC1 MUTE_ALL Q2 GND MUTE_ALL Q1 GND MUTE_MIC1 AUDIO OUT Switchover between and 100V 4 16...

Page 12: ...20mV 10K unbalanced RCA connection terminal EMC input 775mV 40mV 10K balanced European terminal 120W 4 16 100V 240W 350W 500W MIX OUT 1000mV 470 unbalanced RCA connection terminal Bass 10dB at 100Hz...

Page 13: ...4 16 NC NC ON OFF POWER MIC1 INPUT PROT MIC 4 AUX 1 AUX 2 MIC 3 MIC 1 MIC 2 MASTER 100V SIG CLIP TREBLE BASS 10 0 10 0 10 0 10 0 10 0 10 0 4 16 Over 100 44 48 484 44 295 6 10 DIMENSIONAL DIAGRAM 13 U...

Page 14: ...PUBLIC ADDRESS SYSTEM VersionV0 1...

Reviews: