background image

 SAFETY PRECAUTIONS

4

An all-pole mains switch with a contact separation of at least 3 mm in each pole shall be incorporated in
the electrical installation of the building.

When Installing the Unit

     Never   plug  in   nor remove the power  supply   plug
    with  wet  hands,  as  doing  so  may cause electric
    shock.

     When unplugging   the  power   supply cord, be sure
     to grasp the   power  supply   plug; never  pull on the
    cord  itself.  Operating   the  unit   with  a  damaged
    power  supply  cord  may  cause  a  fire  or  electric 
    shock.

     When moving the unit, be sure  to remove its power 
     supply cord   from the  wall   outlet.  Moving   the unit
     with the   power  cord   connected  to   the outlet may
     cause damage to the power cord,  resulting in fire or 
     electric shock. When   removing the power cord,  be
     sure to hold its plug to  pull.

  Do not block the ventilation slots in the unit's cover.
  Doing so may cause heat to build up inside the unit 
  and result in fire.

  Avoid installing the unit in humid or dusty locations,
  in locations exposed to the direct sunlight, near the 
  heaters, or in locations generating   sooty smoke or
  steam  as  doing  otherwise  may  result  in  fire  or 
  electric shock.

When the Unit is in Use

     Do not place heavy objects on the unit  as  this   may
    cause   it  to  fall  or  break   which   may   result   in 
    personal   injury    and/or    property    damage.   In
    addition,  the  object  itself  may  fall  off  and  cause
    injury  and/or  damage.

    Make  sure   that   the  volume   control   is   set   to
    minimum  position   before  power  is  switched   on.
     Loud noise produced at high volume when power  is 
    switched  on  can  impair  hearing.

     Do not operate   the  unit   for an  extended   period of 
     time with   the sound distorting. This  is   an indication
     of   a  malfunction,   which  in   turn  can cause heat to
     generate and result in a fire.

     Contact your ITC dealer as   to the  cleaning. If   dust
    is  allowed  to accumulate  in  the  unit  over  a  long 
    period of  time, a  fire  or  damage  to  the  unit  may 
    result.

  If dust accumulates on the power supply  plug or in
  the  wall  AC  outlet,  a  fire  may  result.  Clean  it 
  periodically. In addition, insert the plug in the wall 
  outlet securely.

  Switch off   the  power, and unplug the power   supply
  plug   from the  AC outlet   for  safety   purposes when 
  cleaning   or  leaving the unit unused for   10  days or 
  more. Doing otherwise   may cause a fire  or   electric 
  shock.

Due to product upgrades, while some of the features and specification in the user manual does not 
match the actual functions, sorry for any inconvenience and  thanks for your kind understanding!

Summary of Contents for T-6241

Page 1: ...PUBLIC ADDRESS SYSTEM T 6241 Please follow the instructions in this manual to obtain the optimum resultsfrom this unit We also recommend that you keep this manual handyfor future reference POWER ON AU...

Page 2: ...NTENTS 2 1 SAFETY PRECAUTIONS 3 2 GENERAL DESCRIPTION 5 3 FEATURES 5 4 NOMENCLATURE AND FUNCTIONS 4 1 Front Panel 6 4 2 Rear Panel 6 5 APPLICATIONS 7 6 SPECIFICATIONS 8 7 BLOCK DIAGRAM 9 8 DIMENSIONAL...

Page 3: ...s doing so may result in fire or electric shock Be sure to replace the unit s terminal cover after connection completion Because high voltage is applied to the speaker terminals never touch these term...

Page 4: ...ock When the Unit is in Use Do not place heavy objects on the unit as this may cause it to fall or break which may result in personal injury and or property damage In addition the object itself may fa...

Page 5: ...al 2 0 7V 1V 1 2V audio output connection for amplifier 3 100V input connection for amplifier The T 6241 series is equiped with audio amplifier receiver module They are designed to suit all PA system...

Page 6: ...CLATURE AND FUNCTIONS 4 1 FRONT PANEL 3 POWER Power indicator 1 2 3 6 AUDIO OUTPUT 0 7V 1 0V 1 5V 24VDC OUTPUT 100V INPUT USE ONLY WITHA 250V FUSE 24VDC 1A AUDIO INPUT 4 5 6 7 4 220V 240V 50 60Hz Powe...

Page 7: ...CATIONS REAR PANEL CONNECTIONS AUDIO OUTPUT 0 7V 1 0V 1 5V 24VDC OUTPUT 100V INPUT USE ONLY WITHA 250V FUSE 24VDC 1A AUDIO INPUT T 60 120 240 350 MIXER AMPLIFIER T 6350 6500 6650 POWER AMPLIFIER REMOT...

Page 8: ...PONSE 0 7V 1 0V 1 5V AUDIO INPUT 100V 100Hz 18KHz 3dB AUDIO AMPLIFIER RECEIVER MODULE DIMENSION mm NET WEIGHT GROSS WEIGHT 484X128X45 POWER REQUIREMENTS 4 5Kg 3 3Kg 8 220 240V 50 60Hz Specific voltage...

Page 9: ...220V 240V Rectification KM 1 1 5V 1V 0 7V 100V Voice KM EB 7 BLOCK DIAGRAM 9...

Page 10: ...er 100 8 DIMENSIONAL DIAGRAM UNIT mm 6 41 41 128 122 45 51 440 484 UNIT mm POWER ON AUDIO ON OFF AUDIO OUTPUT 0 7V 1 0V 1 5V 24VDC OUTPUT 100V INPUT USE ONLY WITHA 250V FUSE 24VDC 1A AUDIO INPUT POWER...

Page 11: ...PUBLIC ADDRESS SYSTEM PUBLIC ADDRESS SYSTEM VersionV0 1...