ITC IJS2000 Operator'S Manual Download Page 8

8

ENGLISH

FRANÇAIS

WARNING! 

 

DO NOT

 connect the black negative (-) booster clamp to the nega

-

tive terminal of your battery.  Connecting to the battery’s negative terminal 

can cause sparking in close proximity to the battery’s natural explosive gases, 

leading to a dangerous explosion.  Once the cables are connected, 

DO NOT 

wiggle the clamps around trying to make a better connection.  This can cause 

sparking and is an explosion hazard.

7.  Start your vehicle. 

WARNING!

 

Be careful of moving parts such as belts, pulleys, or fan blades in the 

engine compartment that can cause injury.

8.  Disconnect the black negative clamp first. Return it to the safety shield marked 

(-) for negative.  Insert it, lifting it up and moving it over the hook in the side of 

the housing.

9.  Disconnect red positive clamp.  Return it to the safety shield marked (+) for 

positive.

NOTE:

 

If your vehicle does not start within 10 seconds, allow the Jumpstart 

system’s internal battery to cool for 3 minutes before attempting to start the 

vehicle again. 

NOTE:

 

If your vehicle battery is so dead that its ignition light does not come on, 

let the Jumpstart remain connected to the battery for 10-20 minutes before 

attempting to start the vehicle.

CAUTION:

 

DO NOT

 attempt to operate 12 volt accessories from the Jumpstart

 

system while trying to start a vehicle.

POWER SUPPLY FOR 12 VOLT ACCESSORIES

The three 

12 volt cigarette-lighter type power outlet

s (

A, fig.1

) on the control 

panel will operate most 12 volt accessories with a draw of 10 amps or less through 

cigarette-lighter adaptors. When fully charged, the Jumpstart system will supply 

power to a 10 amp accessory for approximately one hour, a 6 amp accessory for 

approximately two hours, and a 4 amp accessory for approximately three hours.

1.  Make sure the 

12 volt power outlet on/off switch

 (

H, fig.1

) on the control 

panel is in the “OFF” position (the side of the switch marked “O” is depressed). 

2.  Remove the protective rubber cover from the 

12 volt cigarette-lighter-type 

power outlet

s (

A, fig.1

) and plug in your 12 volt accessory’s cigarette-lighter 

adaptor. 

3.  Turn the 

12 volt power outlet on/off switch

 (

H, fig.1

) to the “ON” position 

(depress the side of the switch marked “I”).

NOTE:

 

The 

12 volt cigarette-lighter-type power outlet

s (A, fig 1) are protected 

by a fuse that prevents damage to the unit in case of short circuit or overdraw 

current. 

1.  If the fuse blows, turn the 

master power switch

 (

H, fig.1

) off (depress the side 

of the switch marked “O”).

2.  Disconnect the 12 volt accessory.  

3.  Replace the blown fuse with another 15 amp of identical type.   

4.  Have the 12 volt accessory checked for possible defects before re-connecting.

AIR COMPRESSOR

CAUTION: 

Do not over-inflate!  Check the manufacturer’s air pressure require

-

ments for what you are inflating and watch the pressure gauge on the front of 

the Jumpstart.  This compressor is capable of putting out 250 psi, but it is a 

light-duty unit; it does not produce a large volume of air, so it may take some 

time to inflate larger objects. 

1.  To use the compressor, open the 

rear compartment cover

 (

P, fig.2

) located on 

the back of the unit by depressing the 

rear compartment locking tab

  

(

O, fig.2

). 

2.  Pull out the 

air hose and nozzle

 (

Q, fig.2

). 

3.  Make sure the nozzle lever is in the up position, in line with the metal chuck’s 

body (fig 2 shows the lever folded down). 

OPERATING PROCEDURES

!

!

!

!

Summary of Contents for IJS2000

Page 1: ...reference CONSERVEZ CE GUIDE Vous aurez besoin de ce guide pour les instructions de s curit les proc dures d utilisation et la garantie Conservez le dans un endroit s r et sec pour r f rence future P...

Page 2: ...d from potential sources of damage heat oil solvents sharp edges or moving parts Replace damaged cords immediately 6 WHEN WORKING OUTDOORS USE AN OUTDOOR RATED EXTENSION CORD An extension cord rated f...

Page 3: ...D REPAIRS should be made by qualified repair technicians at an authorized repair centre Improperly repaired tools could cause serious shock or injury 22 EMPLOYER MUST ENFORCE COMPLIANCE with the safet...

Page 4: ...hes indicators and power jacks are located on an up front convenient control panel 3 cigarette lighter power outlets for powering multiple 12 volt devices LED battery condition indicators Input chargi...

Page 5: ...ttery DC Output 12 volt Current provides up to 900 peak amps 500 cranking amps boost rate Compressor 250 psi 1723 kPa Air hose 580 mm 2 air hose with quick connect thumb lock chuck Work Lights 12 volt...

Page 6: ...running 3 Remove the 12 volt DC cigarette lighter adaptor charging plug and cable U fig 2 from the rear storage compartment 4 Plug the 12 volt DC cigarette adaptor charging plug into your vehicle s c...

Page 7: ...2 Make sure the vehicle s accessories i e lights AC heater radio etc are all turned off 3 For maximum power make sure all switches on the Jumpstart control panel are turned off depress the side of th...

Page 8: ...Jumpstart system will supply power to a 10 amp accessory for approximately one hour a 6 amp accessory for approximately two hours and a 4 amp accessory for approximately three hours 1 Make sure the 12...

Page 9: ...or 5 minutes Over use could cause over heating and motor failure WORK LIGHT The twin work lights F fig 1 are switched by the work light on off switch K fig 1 located at the top of the front panel 1 Tu...

Page 10: ...replacement or credit Any item not listed as over the counter warranty must be shipped prepaid freight to an authorized repair depot accompanied by a copy of the invoice specifying the date that the...

Page 11: ...isez pas un outil pour une fin impr vue lors de sa conception 5 PRENEZ SOIN DU CORDON D ALIMENTATION Ne transportez jamais votre outil par le cordon d alimentation Ne tirez pas sur le cordon pour le d...

Page 12: ...NT Regardez ce que vous faites et servez vous du gros bon sens N utilisez aucun outil lorsque vous tes fatigu 19 V RIFIEZ QUE LES PI CES NE SONT PAS ENDOMMAG ES Avant d utiliser cet outil toute pi ce...

Page 13: ...AS UNE BATTERIE DE V HI CULE SI ELLE EST GEL E 10 NE LAISSEZ PAS LES PINCES DE CONTACT SE TOUCHER ou toucher un morceau de m tal en m me temps Ce produit a t con u et fabriqu avec soin dans le but de...

Page 14: ...r J Poign e de transport K Bouton d alimentation de la lampe de travail L Interrupteur principal et bouton de test de la batterie M Jauge de pression d air du compresseur N Pince de survoltage positiv...

Page 15: ...t la position d arr t O 2 Retirez l adaptateur CA et la fiche d alimentation DC T fig 2 du comparti ment de rangement arri re 3 Branchez l adaptateur CA dans une prise murale de 120 volts CA Branchez...

Page 16: ...rable Lorsque l appareil n est pas utilis rechargez la batterie une fois par mois l aide du chargeur TAT DE LA BATTERIE 1 Mettez l interrupteur principal du panneau de commande la position d alimentat...

Page 17: ...rait entra ner un court circuit momentan dans la batterie ou dans le syst me lectrique causant des dommages co teux l quipement lectronique du v hicule 7 Branchez bien la pince de survoltage n gative...

Page 18: ...d fectuosit COMPRESSEUR D AIR MISE EN GARDE Ne gonflez pas trop V rifiez les exigences du fabricant en mati re de pression d air pour l article gonfler Surveillez le manom tre situ l avant du survolt...

Page 19: ...r l utilisateur N utilisez pas le compresseur d air comme un respirateur Ne dirigez pas l air comprim vers le corps L introduction d air comprim dans des orifices ouverts travers la peau ou sur les bl...

Page 20: ...e Si le produit ne se trouve pas sur cette liste il doit tre retourn franco de port un centre de service autoris par JET accompagn de la facture indiquant la date d achat Il n y aura aucune r paration...

Page 21: ...21 FRAN AIS ENGLISH SCHEMATIC DRAWING SCH MA...

Reviews: