background image

An all-pole mains switch with a contact separation of at least 3 mm in each pole shall be incorporated in
the electrical installation of the building.

When Installing the Unit

     Never   plug  in   nor remove the power  supply   plug
    with  wet  hands,  as  doing  so  may cause electric
    shock.

     When unplugging   the  power   supply cord, be sure
     to grasp the   power  supply   plug; never  pull on the
    cord  itself.  Operating   the  unit   with  a  damaged
    power  supply  cord  may  cause  a  fire  or  electric 
    shock.

     When moving the unit, be sure  to remove its power 
     supply cord   from the  wall   outlet.  Moving   the unit
     with the   power  cord   connected  to   the outlet may
     cause damage to the power cord,  resulting in fire or 
     electric shock. When   removing the power cord,  be
     sure to hold its plug to  pull.

  Do not block the ventilation slots in the unit's cover.
  Doing so may cause heat to build up inside the unit 
  and result in fire.

  Avoid installing the unit in humid or dusty locations,
  in locations exposed to the direct sunlight, near the 
  heaters, or in locations generating   sooty smoke or
  steam  as  doing  otherwise  may  result  in  fire  or 
  electric shock.

When the Unit is in Use

     Do not place heavy objects on the unit  as  this   may
    cause   it  to  fall  or  break   which   may   result   in 
    personal   injury    and/or    property    damage.   In
    addition,  the  object  itself  may  fall  off  and  cause
    injury  and/or  damage.

    Make  sure   that   the  volume   control   is   set   to
    minimum  position   before  power  is  switched   on.
     Loud noise produced at high volume when power  is 
    switched  on  can  impair  hearing.

     Do not operate   the  unit   for an  extended   period of 
     time with   the sound distorting. This  is   an indication
     of   a  malfunction,   which  in   turn  can cause heat to
     generate and result in a fire.

     Contact your 

dealer as  to the   cleaning. 

    If  dust   is  allowed  to accumulate  in  the  unit  over  
    a  long  period of  time, a  fire  or  damage  to  the  unit 
     may  result.

ITC

  If dust accumulates on the power supply  plug or in
  the  wall  AC  outlet,  a  fire  may  result.  Clean  it 
  periodically. In addition, insert the plug in the wall 
  outlet securely.

  Switch off   the  power, and unplug the power   supply
  plug   from the  AC outlet   for  safety   purposes when 
  cleaning   or  leaving the unit unused for   10  days or 
  more. Doing otherwise   may cause a fire  or   electric 
  shock.

 SAFETY PRECAUTIONS

4

Summary of Contents for T-8000A

Page 1: ... instructions in this manual to obtain the optimum resultsfrom this unit We also recommend that you keep this manual handyfor future reference OPERATION MANUAL T 8000A 8 ZONE PAGING MIC AUDIO AUDIO PUBLIC ADDRESS SYSTEM ...

Page 2: ...2 TABLE OF CONTENTS 1 SAFETY PRECAUTIONS 3 2 DESCRIPTION 5 3 FRONT AND REAR PANEL FRONT PANEL 6 4 FRONT AND REAR PANEL REAR PANEL 8 5 CONNECTION AND SETTINGL 9 6 OPERATION GUIDANCE 10 ...

Page 3: ...Should the following irregularity be found during use immediately switch off the power disconnect the power supply plug from the AC outlet and contact your nearest dealer Make no further ttempt to operate the unit in this condition as this may cause fire or electric shock If you detect smoke or a strange smell coming from the unit If water or any metallic object gets into the unit If the unit fall...

Page 4: ...g sooty smoke or steam as doing otherwise may result in fire or electric shock When the Unit is in Use Do not place heavy objects on the unit as this may cause it to fall or break which may result in personal injury and or property damage In addition the object itself may fall off and cause injury and or damage Make sure that the volume control is set to minimum position before power is switched o...

Page 5: ...convenient layout but also integration of RS 485 communication and audio transmission together 4 Extra DC 24V power supply is needed to power the remote one paging microphone a power adaptor is included together within the microphone packaging 5 Eight zone selector with state indication 6 Talk and all zone paging swift keys are provided 7 2 and 4 tones chimes with selector and off switch 8 Volume ...

Page 6: ...f that the talk indicator will be fast flash extinguished 6 ALL CALL BUTTON Push the all call button to select all zones The all call indicator will be extinguished when all call button is pushed while some zone is already been taken in this case the busy zone indicator will be fast flash to amber while the available zone indicator will be illuminated on blue All zone indicators will be illuminate...

Page 7: ...ission from the matrix and the indicator will be illuminated on blue after got matrix communication permission which means ready for announcement The indicator will be illuminated on amber means busy when the zone is already been taken When the zone indicator is on amber the zone could not be selected for paging and comes with phenomena that the indicator will be on amber and fast flash Push back ...

Page 8: ...rt is designed by RJ45 port it is used to communicated with the matrix 14 MIC VOLUME CONTROL It is used to adjust the microphone output volume clockwise adjustment to increase the level 15 CHIME VOLUME CONTROL It is used to adjust the chime volume clockwise adjustment to increase the level 16 CHIME SELECTOR The selector is designed of three options 2 tone off and 4 tones this chime is used to ask ...

Page 9: ... setting There are 4 address codes on both remote paging console and extension keypad which are used to identify itself Notice 1 Only one address code swtich of each dipswitch shall be placed down position otherwise the system maybe will out of work 2 Any of the dipswitches shall be set of different addresses otherwise the system maybe will out of work Connection through 10P IDE cable Extension ke...

Page 10: ...which means announcement could be started while the indicator is extinguished which means announcement is terminated 6 2 2 Talk button could be enabled only after zone selection In case of without zone selection the talk indicator will be fast flash to extinguish if the talk button is pushed The announcement will be terminated immediately as soon the zone selection is canceled and it comes with th...

Page 11: ...PUBLIC ADDRESS SYSTEM VersionV0 1 ...

Reviews: