Green Heating Technology
12
SERVICE
Manual
City Class F-FR
Hydraulic components F
1 Flue pressure switch
2 Flue hood
3 Expansion vessel
5 Safety thermostat on system flow
6 Temperature Sensor, system flow
7 Motorized 3-way valve
8 Automatic Venting Device
(heating circuit, incorporated in the pump)
9 Safety valve 3 bar
10 Pump
11 Drain valve
12 Priority flow switch (with filter)
13 Loss of water pressure switch
14 Gas valve
15 DHW temperature sensor
16 System pressure gauge
17 Filling valve
18 By-pass (in-built in the 3-way valve hydraulic
assembly)
19 DHW exchanger (thermally insulated)
20 Burner
21 Primary exchanger
22 Sealed chamber
23 Fan
30 Check valve
R Heating return
M Heating flow
C Hot water outlet
F Cold water inlet
G Gas inlet
F
00355 00
M
22
23
18
17
21
20
13
10
8
3
9
11
1
7
6
5
2
14
19
15
30
R
M
C
F
G
12
16