26
INSTALLER
fITTING SILumINA frAmE ASSEmBLY for
INSTALLATIoN oN ComBuSTIBLE or WooDEN
WALL
This assembly is suitable for walls between 100 mm
and 500 mm thick.
- Having chosen the position for the heater in accor-
dance with the installation booklet for the heater, cut
a hole through the wall, with these dimensions: dia-
meter (A).
The hole in the wall as neatly as possible to enable
the flue assembly to be installed both straight and
level through the wall.
- Fit the silumina frame assembly to the wall, as follows:
1) Measure the wall thickness, not including the
stainless-steel plate and cut the tube (2) to length
equal to the wall thickness.
Fit the internal tube, (2) inside the opening cut in the wall.
Fit the metal plate (5) to the inside of the wall, using
the 4 screws with anchors for wooden walls provi-
ded, for fixing the plate on the wall. Fit the cut tube to
the wall working from inside the building, ensuring
that it fits within the lugs on the stainless-steel plate.
Fit the internal wall plate so that the 4 screws (1) on
it fit inside the tube.
2) Fit the external stainless - stell (3) AISI 304 to the
outside of the wall using the 4 screws, included in
the pack, if the external wall is hard stone chose
screws and anchors suitable for stone walls.
Use a water resistant compound (e.g. Secomasic or
Silastic) between the plate and the wall to prevent
rainwater reaching the interior of the wall.
PROTECTION FOR WALLS MADE OF WOOD PANELS
MOD.
3.0
5.0
3 2
A
9 0
mm
7.0
(mm)
(mm)
9.0
5 4
1 3 0
mm
L
5 0 0
(mm)
5 0 0
L