Chance A2 with Ø 54 mm tubes
To install the fume exhaust and air extraction pipes:
- mark the centre (A) and make the hole B (Ø 65 mm
for the pipe Ø 54 mm).
- make the recess in the wall to house the curve and
remaining pipes.
- WALL installation: fasten the template to the wall
using the Ø 8 mm screw anchors provided. Use the
holes C.
- CORNER installation: rest and fasten the brackets
(D) above the template using the holes C. Fasten the
TBrackets to the corner walls, using the
holes E on the brackets.
If you find difficult to mark the hard covering for
the adepter connection hole, you need to perfo-
rate the two holes with the bit Ø 6 mm to this use the
template. For normal plaster is enough to get throu-
gh the fastening holes with the bit of Ø 3 mm.
Group adapter connection tube
-- With Ø 54 mm tubes
- Assemble the die-cast angle curves (6 - only for 0
54mm tubes), on the adapter connection then fasten
in position with the furnished screws.
- Rotate the curves (6) to the point that you can close
the flange (1) with the screws (2). Assemble the tem-
plate to the wall, and the assemble group.
- Complete the installation with the tubes, cut the
tubes at measure (5) adapting to the actual increa-
sed wall space of 25mm, eliminating the part in
excess, making that the tube will be at thread with
the terminal hole (4).
Ascertain that the adapter tubes connection is cor-
rectly inserted. To fasten the tubes assemblage, use
silicone grease and verify that the O ring don’t come
out from its seating.
1
Ø 54
5
2
4
3
6
2
1
+25mm
Ø 54
21
INSTALLER
Min.
150
Min.
150
770
A
B
C
C
D
D
E
E
Summary of Contents for Fiammella
Page 1: ......
Page 40: ...3520300030 Rev 1...