Page 1: ......
Page 2: ...COMPLIANCE Our appliance are compliance at Gas directive 90 396 CEE Electromagnetic directive compatible 89 336 CEE Low tension directive 73 23 CEE 0694 RANGE F i a m m e l l a MODEL CODE F M 4 0 R 2...
Page 3: ...l be long lasting reliable when it is installed and used properly manufacturer s guidelines are followed Good work and thanks The Manufacturer 3 GENERAL WARRANTY Provided that it is fitted in accordan...
Page 4: ...ical collegaments pag 25 Gas connection pag 26 CUSTOMER SERVICE Preliminary operations pag 26 First service start pag 27 Processor control box malfunction pag 28 Controls during the first after starti...
Page 5: ...nt to Art 17 of law no 46 90 and the instructions provided by the Manufacturer in the installer s booklet that accompa nies the product The APPLIANCE must be used as intended by the Manufacturer and f...
Page 6: ...the apparatus The appliance is a gas radiator that heat up the atmosphere It has an intake of air that goes in the combustion chamber type C The appliance is made with an aluminium body that allows a...
Page 7: ...tion fan 12 Combustion chamber 13 Pressure switch 14 Battery holder buffer batteries 15 Control unit 16 Combustion fan 17 Ignition electrode 18 Detection electrode 19 Air extraction pipe 20 Digital co...
Page 8: ...230 50 135 IP20 3 96 3 41 2 9 LPG 28 8 36 4 0 354 0 228 0 62 95 160 17 21 Methane 12 0 0 407 0 285 1 10 95 160 43 7 5 Methane G30 G31 kg h 0 349 0 225 Main pressure nomination mbar 29 37 20 DESCRIPTIO...
Page 9: ...ional VC COMBUSTION FAN VTC TANGENTIAL CENTRIFUGAL FAN CN CONNECTOR T1 POWER TERMINAL VT TANGENTIAL FAN TA IGNITION TRANSFORMER GND 24V REMOTE CONTROL POWER SUPPLY TX RX SIGNAL TRANSMISSION RETURN BL...
Page 10: ...enu line d Press SELECT key key 5 note keys 1 2 4 and 5 acquire different functions in the different menus required setting e Press keys 1 and 2 to set the required parameter f Press key 4 to store th...
Page 11: ...union for 54 mm pipes 4 3 9 mm screws for fastening adapter 4 8 mm screw anchors for fastening template 2 54 mm pipes L 500 mm 1 Single end piece with integrated rosette 4 6 mm screw anchors for fast...
Page 12: ...L CODE T P 5 4 0 P 0 0 0 0 0 description KIT std EXHAUST INTAKE 54mm 1 INDIVIDUAL T P 5 4 S P 0 0 0 0 0 KIT special EXHAUST INTAKE 54mm 2 SINGLES KIT special EXHAUST INTAKE 54mm 1 INDIVIDUAL INTERNAL...
Page 13: ...Height B mm 1070 Width C mm 542 Depth A mm 351 Weight kg 43 DESCRIPTION fiammella 13 INSTALLER WEIGHT DIMENSION c b a...
Page 14: ...k if around the appliance tubes there are mate rials that can support the heath second check if the wall is made of the right material and can support the appliance weight Verified if around the exhau...
Page 15: ...f more 200 C ex HT Armaflex of temperature Realize the holes for fastening the tubes after establish the hangers length insert it in the right position Before assembling the tubes kit verifying that t...
Page 16: ...rner and level mark the holes B 8 mm to fasten the template to the two corner walls mark the centre point C on the wall and then make the hole for the extraction and exhaust pipes make a 110 mm hole i...
Page 17: ...from the out side Insert in the wall the assembled group adapter con nection angles and curves Position the unloaded intake tubes at thread outside wall being real careful that the short tube is alway...
Page 18: ...dicated when the exhaust fumes and intake are fore way the apparatus The type of installation are more than one kind but they can be lead to the 3 example described in this chapter Before pipes kit as...
Page 19: ...rs provided Use the holes C CORNER installation rest and fasten the brackets D above the template using the holes C Fasten the Template Brackets to the corner walls using the holes E on the brackets W...
Page 20: ...le the two flanges 1 unscrew the screws 2 take off the reductions 3 only for the 0 32mm tubes then assemble the group Assemble the unique terminal 4 to tube 5 The cut has to be perpendicular to the ax...
Page 21: ...er is enough to get throu gh the fastening holes with the bit of 3 mm Group adapter connection tube With 54 mm tubes Assemble the die cast angle curves 6 only for 0 54mm tubes on the adapter connectio...
Page 22: ...furnished screws Complete the installation assembling it with the rest of the tubes fastening them to the wall with commercial clamps Chimneypot assemblage To assemble the chimneypot on the unloaded...
Page 23: ...nloaded fumes 3 before assembling the ter minal Approach the apparatus inserting the unloaded intake fumes curves in the right adapter connection tubes To fasten the tubes use grease and be sure that...
Page 24: ...ol away from the appliance max 2 95 m This standard solution has been conceived to read the best comfort room temperature In this position in fact the remote control senses a temperature at human heig...
Page 25: ...ket provided and making an EARTH connection that is 2 cm longer than the PHASE and NEUTRAL leads Connect the other end of the cable to a socket or omnipolar switch in conformity with CEI standards con...
Page 26: ...nt to realize a good ground connection and to respect the neutral phase During the first starting you might verify vapour and irritating smells not dangerous To avoid these discomfort we advice to aer...
Page 27: ...desired fan speed set timer function on manual mode After startup the appliance runs until it reaches the set room temperature operation signal on the display goes off In case of malfunctions in start...
Page 28: ...the gas pressures are as under the Table The gas pressure value has to be as in the table The apparatus execute a stop and next restart Operating from the main control panel Operate on the atmospheri...
Page 29: ...r 5 and disk 8 Unscrew the 3 injectors 6 change them with the new ones Be real careful when you fasten the injec tor check on the injector that it has the right values as in the table The injectors se...
Page 30: ...as spe cified in the table To make a regulation operate on the screw that is on the modulator body 4 Rotating the regulator screw 3 clockwise the pressure decrease rotating counter clockwise the pres...
Page 31: ...h to the off position Close the gas tap Wait that the appliance gets cold completely Cover clean The only cleaning that is required by the owner involves removing the cover and wiping it clean the dus...
Page 32: ...ittle brush with metallic hair for cleaning after insert the electrode group 1 o 2 if necessary exchange the seal gasket 4 be real careful to not damage the electrode Pressure switch tubes Check that...
Page 33: ...mbustion chamber 6 Disassemble a half sleeve 4 with the clamp 2 and after the fan 5 Unscrew the screw away the fan frame complete of curves connector 7 and ant vibration gasket 8 Disassemble the curve...
Page 34: ...trips if the convection fan is not working properly or anomalous overheating occurs and or the outflowing air temperature reaches over 107 C disengaging the burner closing the gas valve and stopping...
Page 35: ...witch from the frame Reassemble the new pressure switch Insert the silicone tubes 3 o 4 also be real careful when you reconnect the cables if you are not sure of what you are doing look at the electri...
Page 36: ...ures Thermostat fails to engage Adjust the thermostat Burnt out fuse Replace Control board faulty Replace High room temperature Room thermostat set too high Air in gas pipes Bleed Incorrect ignition e...
Page 37: ...as replace Power of appliance not enough for installation premises Replace the appliance with a more powerful one Faulty control board Replace The tangential fan does not work Faulty motor Replace Fau...
Page 38: ...Sig Venditore Via tel Sig Installatore Via tel Sig Servizio Tecnico di Assistenza Via tel Data Intervento USEFUL INFORMATION 38 CUSTOMER SERVICE...
Page 39: ...er Uno solo Un seul Only one Pi di uno Plusieurs More than one Compilare tutto in STAMPATELLO Remplir en caract res d imprimerie To write blockletters n Contratto di manutenzione programmata Abonnemen...
Page 40: ...3520300030 Rev 1...