6
ENGLISH
the manufacturer reserves the right to modify the product at his own discretion and without
notification.
tecHnical Data
* The heatable volume is calculated for a house insulated pursuant to Italian Law 10/91 and subsequent amendments,
and a heating demand of 33 Kcal/m³ hour.
electRical sPecifications
Power supply
230 V AC +/- 10% 50 Hz
on/off switch
yes
Mean absorbed power
80-60 W
Power absorption during ignition
320
Protection on mains power supply
Fuse T2A, 250 Vac 5x20
Logic board protection
Fuse T4A, 250 V AC 5x20
®
UseR/installeR
tecHnical sPecifications as per en 14785
The above data is for guidance only and was taken during the certification phase by a notified body under the
conditions specified by the standard.
layMa iDRo 22 layMa iDRo 18
layMa iDRo 22
layMa iDRo 18
Nominal power
Reduced power
Available power
22,5
18,7
4,9
kW
Power available to water
20
16,3
3,8
Efficiency
92,7
93,3
95,1
%
CO emissions at 13% O
2
0,012
0,013
0,007
%
Fumes temperature
114
101
54
°C
Fuel consumption
5,1
4,2
1,1
kg/h
Tank capacity
37
kg
Recommended draught
11
11
11
Pa
Autonomy
9
7
33
hours
Water content
20
l
Maximum operating pressure
2
bar
Maximum operating temperature
90
°C
Heatable volume *
585
485
m
3
Fumes outlet diameter (male)
80
mm
Air intake diameter (male)
50
mm
Weight including packaging
260
kg
tecHnical Data foR Rating tHe flUe
which must in any case satisfy the requirements of this sheet and the installation instructions for the product
Nominal power
layMa iDRo 22
layMa iDRo 18
Fumes temperature at smoke outlet
137
122
°C
Minimum draw
0,01
Pa
Fumes flow rate
15,1
13,4
Rps
Summary of Contents for LAYMA IDRO 18
Page 1: ...LAYMA IDRO 18 22 GB Installation use and maintenance page 2 Pellet boiler stove...
Page 34: ......
Page 35: ......