background image

LAYMA IDRO

 18-22 

®

GB  Installation, use and maintenance 

page 2

Pellet boiler stove

Summary of Contents for LAYMA IDRO 18

Page 1: ...LAYMA IDRO 18 22 GB Installation use and maintenance page 2 Pellet boiler stove...

Page 2: ...reference LAYMA IDRO 18 Performance declaration DoP EK n 154 LAYMA IDRO 22 Performance declaration DoP EK n 155 Moreover the company hereby declares that the LAYMA IDRO 18 22 wood pellet boiler stove...

Page 3: ...Proper commissioning is required for activation of the manufacturer s warranty The warranty is only valid in the country where the product was bought If the appliance is not commissioned by an author...

Page 4: ...t may become soiled the flue may catch fire and environmental damage may ensue cleaning the combustion chamber when hot DO NOT CLEAN THE COMBUSTION CHAMBER WITH A VACUUM CLEANER WHILE IT IS HOT Risk o...

Page 5: ...DIMENSIONS cm 62 60 5 120 120 62 5 cm combustion air 8 cm smoke outlet 14 47 14 USER INSTALLER The hydraulic connections depend on the optional extras kit Instructions are provided in the hydraulic i...

Page 6: ...nditions specified by the standard LAYMA IDRO 22 LAYMA IDRO 18 LAYMA IDRO 22 LAYMA IDRO 18 Nominal power Reduced power Available power 22 5 18 7 4 9 kW Power available to water 20 16 3 3 8 Efficiency...

Page 7: ...ions Do not turn the package over and handle all parts requiring installation with care PACKAGING details in the cladding paragraph The delivery consists of 3 packages one 1 containing the stove s fra...

Page 8: ...ers matching instructions 1 remove the two brackets screwed to the front 2 remove two brackets screwed to the back of the stove INSTALLER Detail of grille G and pack with removable handle and small pa...

Page 9: ...y useful for the installation but they may not refer to the specific model Open the lid of the pellet tank and take the pipe Unscrew the three screws securing the centring bracket to the back of the s...

Page 10: ...product on the left side this edge identifies the floor HEATING DELIVERY HEATING RETURN SECURITY DISCHARGE COLD H2 O THIS EDGE IDENTIFIES THE FLOOR THIS EDGE IDENTIFIES THE DIMENSION OCCUPIED BY THE P...

Page 11: ...puffer of at least 20 l kW is recommended The return temperature of water to the boiler stove must be higher than 50 55 C to prevent the forming of condensation An accumulator tank is needed to heat l...

Page 12: ...ATING AND DHW BOILER Compatible kits for the boiler are Pipe kit Kit R The heat demand may arise from the environmental probe input if the detected temperature falls 1 C below the set temperature the...

Page 13: ...oard and 2 cableways on the back remove the protective cover fixed by two screws Examples of possible connection configurations are given below The cableways are provided in the pack above the product...

Page 14: ...w In Italy check the compatibility pursuant to UNI 10683 and UNI 7129 in the presence of gas fired products INSTALLATION Protection from heat and safety clearances The surfaces of the building adjacen...

Page 15: ...ss than 1 5 terminate at roof level with a proper chimney pot the flue may not discharge directly on the wall or into an enclosed space even if the space in question is open to the sky be made of mate...

Page 16: ...re air exchange for heating and glass cleaning air etc Indirect air intake The boiler stove draws the air from outside through a hole at the rear Install an air outlet at floor level with an effective...

Page 17: ...ctrical system must be compliant check the operation of the earth in particular Edilkamin is not responsible for malfunctions resulting from an improperly earthed system The power line must be of adeq...

Page 18: ...Ceramic top 4 1 INSTALLER The metal grille for the top is in the neck of the stove structure with three M4 screws washers and two rubber elements for fastening Small parts M4 screws with washers for...

Page 19: ...combustion chamber door using the removable handle M and screw in the ceramic tile using the two M4 screws and washers as shown in the figure and detail image on this page Fitting the ceramic tile to...

Page 20: ...ront panel 2 Screw the ceramic tile onto the metal lower front panel using two M4 screws and washers Fitting the ceramic lower front panel 2 3 Screw the metal lower front panel 2 with ceramic lower fr...

Page 21: ...nto the structure Fitting the side panels 3 The side panels are hooked at the bottom and screwed at the top To adjust the alignment adjust the upper screws in the slots 2 Screw the side panels onto th...

Page 22: ...justments can be made by adjusting the feet supporting the top or as indicated in the instructions for fitting the side panels by adjusting the screws beneath the side panels with the top and side pan...

Page 23: ...e provided gloves when loading the stove while it is operating and hence hot to the touch Take care not to touch the fume exhaust pipe when hot FUEL Use UNI EN ISO 17225 2 category A1 wood pellets or...

Page 24: ...the menu press the button for 2 seconds the LED above the button will go out If you press the button or the button you can browse the following menu DISPLAY DESCRIPTION M1 Set clock M2 Set timer M3 Ad...

Page 25: ...t the water temperature and the required temperature for the room where the boiler stove is installed When the required room temperature AIR or water temperature H2O is reached the boiler stove will a...

Page 26: ...M1 set clock press the button for about 6 seconds External Thermostat It must be connected via the blue cable to the serial port located on the back of the boiler stove It must have a dry normally ope...

Page 27: ...ys of the week such as Weekend Program possibility of 2 switch ON and switch OFF times during the weekend Example start1 week end 07 00 stop1 week end 11 30 Example start2 week end 14 20 stop2 week en...

Page 28: ...oned in its housing if not the glass may break by hitting it Ensure that the grate is properly positioned in its housing following maintenance otherwise the stove may have problems igniting Before doi...

Page 29: ...to a non flammable container the ashes may still contain embers and or hot parts or vacuum if cold Vacuum out the interior of the combustion chamber the bed and the compartment around the grate into w...

Page 30: ...spection window below the combustion chamber should be vacuumed To access it remove the deflector D which is only resting in place After vacuuming reposition the deflector D C D Make sure you have cor...

Page 31: ...the chimney pot catching fire We recommend against using compressed air to clean the combustion air inlet SUMMER SHUTDOWN During the period of disuse keep the stoves doors hatches and lids closed We...

Page 32: ...first alarm threshold of 250 has been exceeded placing the boiler stove in modulation The boiler stove only displays an alarm leading to shutdown when a temperature of 270 has been reached Check the...

Page 33: ...re pellets in the tank Check that the water temperature has not increased due to the closure of a valve call a technician Contact the technician AL7 thermal safety Switching OFF due to excessive overh...

Page 34: ......

Page 35: ......

Page 36: ...code 941394 GB 05 17 C 941394 GB...

Reviews: