Italiana Camini Dida Idro Installation, Use And Maintenance Manual Download Page 18

18

ENGLISH

UseR instRUctions

®

scReW feeDeR filling

Loading the pellet screw feeder (coclea) is only neces-
sary if the boiler stove is new (and being switched on for 
the first time) or if the boiler stove had completely run 
out of pellets.
To activate this loading, press the 

  

 buttons 

simultaneously, and the term “RI” is displayed.
The loading function ends automatically after 240” or if 

you press the 

 button.  

ignition

With the boiler stove in stand-by, (after checking that 

the grate is clean), press the 

 button and the 

ignition procedure starts up. 
The term “ON AC” (combustion starting) is displayed; 
after completing some control cycles and when the 
pellets have actually ignited the term “ON AC” is dis-
played (heating is being turned on).
This phase will last for a few minutes allowing the 
ignition to be completed successfully and the boiler 
stove's heat exchanger to be heated. 
After a few minutes the boiler stove will move to the 
heating phase, indicating the term “burn” and then, 
during operation, it will display the delivery water 
temperature set by the user and the power selected 
by the automatic modulating system. 

sWitcHing off

By pressing the 

 button when the boiler stove is 

ON, the switching off phase is started which involves:

• Interruption to pellet supply
• Consumption of the last pellets in the grate, while 

the flue fan stays on (typically for 10 min.) 

• Cooling down of the boiler stove body maintaining 

the pump in operation until the shutdown temperature 
is reached

• The term “OF” is displayed together with the num

-

ber of minutes until switch-off.
During the switch-off phase, the boiler stove cannot 
be switched on again; once the switch-off phase is 
complete, the system will automatically go back to 
standby.

aUtoMatic oPeRation

It is necessary for the user to set the system delivery 
water temperature; this temperature must be as-
sessed in relation to the type and size of the system, 
also considering the atmospheric temperature linked 
to seasonal use. 
The boiler stove, independently, regulates the power 
according to the difference between the set tempera-
ture (set on the display) and the temperature meas-
ured by the probe; when the desired temperature is 
reached, the stove will operate at minimum power on 
1. You can increase the temperature 

required by pressing the 

 button or reduce it by 

the pressing the 

 button. 

The required temperature and the power that is 
chosen automatically by the electronic modulating 
system are displayed alternately.

econoMy fUnction

Function suitable for boiler stoves installed in small-
scale systems, or in mid-season when even minimum 
power operation causes excessive heating.
This function, managed automatically, allows for 
switching the boiler stove off once the set delivery 
temperature is exceeded. The term “EC OF” will be 
displayed indicating the minutes remaining to switch-
off. 
When the delivery temperature falls below the set 
value, the boiler stove switches back on automatically. 
Request activation of this function, if required, from 
the Technical Assistance Centre during initial start-up.

ReMote actiVation fUnction 

(aUX port)

By means of a special optional connection cable, you 
can turn on/off the boiler stove using a remote device 
such as a GSM remote telephone control, a room 
thermostat, a command from a home automation 
system, or in any case from a device with voltage free 
contact with the following logic:

Contact open

 = boiler stove OFF

Contact closed

 = boiler stove ON

Activation and deactivation occurs 10” after the last 
command was transferred.
If the remote activation port is connected up, you 
can still turn the boiler stove on/off using the control 
panel; the boiler stove will always react in compliance 
with the last order received, whether it is for switching 
ON or switching OFF.

RooM Ventilation

To activate/deactivate the room temperature, press 
the SET button for 3”; when “Air” is displayed, release 
the SET button, and using the +/- buttons set to Air 
ON, if you want to activate ventilation or to Air OFF, if 
you want to disable it. 
Please note: the activation of ventilation is dependent 
on this menu but also on a minimal water temperature 
inside the boiler stove.

Summary of Contents for Dida Idro

Page 1: ...EN Installation use and maintenance page 2 Dida Idro Pellet boiler stove...

Page 2: ...t The pellet boiler stove mentioned below complies with EU Regulation 305 2011 and harmonised EU standard EN 14785 2006 PELLET Boiler Stove bearing the ITALIANA CAMINI trademark and called DIDA IDRO S...

Page 3: ...afety of those using it at risk OPERATING SEQUENCE follow the instructions for the operations described The product is uniquely identified by a number the counterfoil which is indicated on the warrant...

Page 4: ...he product may become soiled the flue may catch fire and environmental damage may ensue cleaning the hearth when hot DO NOT CLEAN THE HEARTH WITH A VACUUM CLEANER WHILE IT IS HOT Risk of damage to the...

Page 5: ...13 19 5 6 57 32 44 55 110 57 8 cm uscita fumi 4 cm aria combustione 55 110 5 10 10 10 ritorno 3 4 mandata 3 4 valvola sicurezza 3 bar 13 19 5 6 57 44 55 4 com 55 110 32 44 110 57 8 cm uscita fumi 4 c...

Page 6: ...requirements of this sheet and the installation instructions for the product Nominal power Reduced power Available power 15 4 8 kW Fumes temperature at outlet 155 67 C Minimum draw 0 5 Pa Fumes flow r...

Page 7: ...ing the structure of the boiler stove with the side panels already installed one 2 with the top Always move the stove vertically with suitable equipment and in observance of safety regulations Do not...

Page 8: ...already fitted while the ceramic top is packed sepa rately fig 1 Position the ceramic top into the special runners on the cast iron top The D 8 washers are used as shims under the rubber supports if...

Page 9: ...same room or area as the product may affect its draw In Italy check the compatibility pursuant to UNI 10683 and UNI 7129 in the presence of gas fired products Protection from heat and safety clearanc...

Page 10: ...e of material rated fire reaction class A1 per UNI EN 13501 or analogous national regulations be certified with a chimney plate if metal be of uniform cross section or vary in cross section only immed...

Page 11: ...igher storey must be at least 50 cm higher than the other it must extend beyond the back flow zone in Italy refer to UNI 10683 point 6 5 8 it must allow for maintenance of the chimney EXTERNAL AIR INT...

Page 12: ...ensure safety If the expansion tank is built into the boiler stove this does NOT ensure proper pro tection against the thermal expansion in curred by water in the entire system Therefore installers s...

Page 13: ...re reducer MI Delivery System P Pump circulator RA Radiators RI Return System S Drain SB Water heater ST Temperature Probe TC Boiler stove V Ball valve VA Automatic air vent valve VEC Closed expansion...

Page 14: ...electronic controller makes the differential pressure vary between the set point value Hs and 1 2 Hs The differential pressure varies with the volume flow rate c Air relief procedure This procedure a...

Page 15: ...green light The pump is ready for operation but does not move The pump starts rotating autonomously as soon as the error disappears Undervoltage U 160 V or overvoltage U 253 V Module overtemperature...

Page 16: ...first few days of use and if the plant has also been partially reloaded The presence of air in the ducts does not allow it to function properly To help with venting operations the valve is equipped wi...

Page 17: ...loaded and waiting for flame to light ON AR Boiler stove in the second stage of ignition heating up of boiler stove body and combustion start up Burn Boiler stove in the phase of heating water exchang...

Page 18: ...boiler stove independently regulates the power according to the difference between the set tempera ture set on the display and the temperature meas ured by the probe when the desired temperature is re...

Page 19: ...ncreases the time by 15 min with each press and using the button which decreases the time by 1 min with each press confirm the setting with the SET button set the current day of the week using the key...

Page 20: ...ers an entire season for a normal average user If the key back lighting comes on when one of the keys is touched this indicates that the remote control is transmitting the signal a beep from the boile...

Page 21: ...fig A placed at the top front underneath the tank lid Open the door of the hearth remove the grate 1 fig B and pour out the residue into the ash tray or suck it up with the vacuum cleaner Scrape the...

Page 22: ...nuts clean the silicone gasket and vacuum the residue in the smoke duct 6 fig C The boiler stove is supplied with a replacement silicone gasket The quantity of residue which forms depends on the type...

Page 23: ...d inspect the system there is an increased risk of the chimney pot catching fire We recommend against using compressed air to clean the combustion air inlet SUMMER SHUTDOWN When the stove is not in us...

Page 24: ...SSAGES AND THEIR SOLUTIONS MESSAGE PROBLEM SOLUTION AL01 Intervenes if the water reading probe is faulty or disconnected Contact the technician AL02 displays when the logic board is not detecting the...

Page 25: ...he gearmotor Contact the technician AL H Intervenes if there are electrical absorption problems on the gearmotor Contact the technician MESSAGES WHICH DO NOT SHUT THE STOVE DOWN BUT ARE SIMPLY WARNING...

Page 26: ......

Page 27: ......

Page 28: ...code 941344 GB 03 17 A 941344 GB...