![Italforni TS Gas Instructions For Use And Maintenance Manual Download Page 7](http://html1.mh-extra.com/html/italforni/ts-gas/ts-gas_instructions-for-use-and-maintenance-manual_2094706007.webp)
Instructions for use and maintenance
7
1.3 Technical information
Tab. 1
Model
TS GAS
External dimension L x P x H
1420 x 2160 x 661 mm
Stand dimension L x P x H
1150 x 1330 x 622 mm
Total nominal thermal capacity
47,0 kW
Reduced thermal capacity
42,5 kW
Electrical power rating
100 W
Gas connection
ISO 7-1 da 3 / 4 “
Appliance category
II2H3+
Type of construction
B
21
Electric security class
I
Voltage supply
220-230 V ~ 50 Hz
Power lead
Tipo H07RN-F 3x1,5 mm
2
Gas connection nominal pressure
Liquid butan/propane gas G30/G31
Natural gas G20
: 28-30/37 mbar
: 20 mbar
Gas pressure at the injector (MAX.)
Liquid butan/propane gas G30/G31
Natural gas G20
: 27 mbar
: 9 mbar
Gas pressure at the injector (MIN.)
Liquid butan/propane gas G30/G31
Natural gas G20
: 21 mbar
: 7 mbar
Gas consumption calculated with calorific
inferior value H
i
at 15° and 1013 mbar :
G 30 : 3,707 kg / h
G 31 : 3,651 kg / h
G 20 : 4,974 m
3
/ h
Main injector diameter
G 30/G 31 : 2 x 255 1/100 mm
G 20 : 2 x 450 1/100 mm
Primary air bushing setting
G 30/G 31 : 2 x 18 mm
G 20 : 2 x 13 mm